Operation Manual

ENGLISH INSTRUCTIONS FOR USE
22
SCRUBTEC 545B / 545BL / 553B / 553BL / BOOST 5 - 9097054000
02/2007
05/2015
VACUUM SYSTEM MOTOR FILTER CLEANING
1. Drive the machine on a level oor.
2. Turn the ignition key (80) to “0”.
3. Open the recovery tank.
4. If necessary, drain the water from the tank in order to make the lter visible.
5. Check that the pre-lter is clean. If necessary clean it with water and compressed air, then install it.
6. Perform steps 1, 2 and 3 in the reverse order.
SOLUTION FILTER CLEANING
1. Drive the machine on a level oor.
2. Turn the ignition key (80) to “0”.
3. Close the solution tap (A, Fig. 7) under the machine, behind the right rear wheel. The valve (A) is closed when it is in the
position (B) and it is open when it is in the position (C).
4. Remove the transparent cover (D), then remove the lter strainer (E). Clean and install them on the support (F).
NOTE
The lter strainer (E) must be correctly positioned on the housing (G) of the support (F).
5. Open the valve (A).
E
G
F
E
D
A
C
B
P100109
Figure 7