Operation Manual

USER MANUAL ENGLISH
SCRUBTEC 234C - 9099346000 9
USE
WARNING!
On some points of the machine there are some adhesive plates indicating:
DANGER
WARNING
CAUTION
CONSULTATION
While reading this Manual, the operator must pay particular attention to the symbols shown on the plates.
Do not cover these plates for any reason and immediately replace them if damaged.
BEFORE MACHINE START-UP
Brush pressure adjustment
The machine is supplied with the brush (20) installed on the
deck.
To install/replace it, see the procedure in “Brush cleaning”
paragraph, under Maintenance chapter.
To adjust the pressure on the oor, turn the knob (Fig. 1) as
shown:
+
Higher pressure Turn the screw to the
right.
-
Lower pressure Turn the screw to the
left.
Solution tank lling
1. Fill the tank (14) with a solution suitable for the work to be
performed.
2. Do not ll the solution tank completely, leave a few
centimetres from the edge (Fig. 2).
3. Always follow the dilution instructions on the label of the
chemical product used to prepare the solution.
4. The solution temperature must not exceed 40°C.
CAUTION!
Use only low-foam and non-ammable
detergents, intended for automatic scrubber
applications.
WARNING!
When using oor cleaning detergents, follow
the instructions on the labels of the detergent
bottles.
To handle oor cleaning detergents, wear
suitable gloves and protections.
Adjustments
5. Adjust the inclination of the handlebar (8) with the lever (9)
to reach a comfortable position.
Figure 1
P100512
Figure 2
P100513