Operation Manual

POSEIDON 4
12
1)
Options / model variants
Original instructions
Maintenance / Troubleshooting
Fault Cause Remedy
Pressure drop Air in the system Vent the system by operat-
ing the spray gun several
times at short intervals.
If necessary, operate the
cleaner for a short time
without the high-pressure
hose connected.
High pressure nozzle blocked
worn
Clean/replace the high
pressure nozzle
Pressure control on the spray
pipe is not set correctly
Set the required working
pressure
Detergent tank empty Top up detergent tank or
set detergent metering to
“0”
Pressure fl uctuations Pump draws in air (only pos-
sible in suction mode)
Check that the suction set
is air-tight
Lack of water Open water tap
Water inlet hose is too long
or its cross-section too small
Use specifi ed water inlet
hose
Lack of water caused by
blocked water fi lter
Clean the water fi lter in the
water connection (never
work without water fi lter)
Lack of water because max.
permissible suction height
has not been heeded
See instructions
The motor does not start when
the cleaner is switched on
The plug is not inserted prop-
erly, i.e. there is no current
Check the plug, lead and
switch and if necessary
have them replaced by a
trained electrician
The mains fuse is switched
off
Switch on the mains fuse
Recycling the cleaner
Make the old cleaner un-
usable immediately.
1. Unplug the cleaner and cut
the power cord.
Do not discard of electrical ap-
pliances with household waste.
As specified in European Direc-
tive 2002/96/EC on old electri-
cal and electronic appliances,
used electrical goods must be
collected separately and recy-
cled ecologically. Contact your
local authorities or your nearest
dealer for further information.
Guarantee