Operation Manual

26
1)
Optional accessories / Option depending on model
Original Instructions
ATTIX 995-0H/M SD XC Type 22
8 Troubleshooting
Fault Cause Remedy
Motor does not start > Fuse of the mains socket has
blown.
Connect mains fuse.
> Overload protection switch
has tripped.
Switch off the vacuum cleaner
and allow it to cool for approx.
5 minutes. If the cleaner
cannot be started again,
contact the Nilfisk-Alto service
department.
> Motor is faulty. Have motor changed by
Nilfisk-Alto Service.
The acoustic warning
sounds. (Reduced suction
power)
> Hose diameter and switch
position do not correspond.
Set correct switch position for
hose diameter.
> Clogged suction hose/nozzle. Clean suction hose/nozzle
> Tank, disposal bag or safety
filter bag is full.
See "Emptying tank" or
"Replacing disposal bag,
safety filter bag" sections.
> Filter element is clogged. See section „Cleaning filter
element“ and „Replacing filter
element“.
> Cleaning mechanism is
defective.
Contact Nilfisk-Alto Service.
No suction power during
wet cleaning
> Tank is full. Switch off the cleaner. Empty
the tank.
Voltage fluctuations > Impedance of power supply is
too high.
Connect the cleaner to
another socket closer to the
fuse box. Voltage fluctuations
over 7% should not occur if
the impedance at the transfer
point is 0.15 .