ATTIX 995-0H/M SD XC Type 22 Operating Instructions ø ø 3 ø6 27 32 ø 5 0 auto 107401246 B
ATTIX 995-0H/M SD XC Type 22 Contents 1 Important safety instructions ............................................................................................2 2 Description 2.1 2.2 Operating elements ..............................................................9 Operating panel ..................................................................10 3 Before starting the cleaner 3.1 3.1.1 3.1.2 3.1.3 3.1.4 Assembling the vacuum cleaner.........................................
ATTIX 995-0H/M SD XC Type 22 1 Important safety instructions Symbols used to mark instructions Prior to using the appliance for the first time, be sure to read this document through and keep it ready to hand. DANGER Danger that leads directly to serious or irreversible injuries, or even death. WARNING Danger that can lead to serious injuries or even death. CAUTION Danger that can lead to minor injuries and damage.
ATTIX 995-0H/M SD XC Type 22 Dust Class M (medium). The dusts which belong to this class are: dusts with OEL values1) > 0.1 mg/m³ as well as saw dust. The machine is tested in its entirety by vacuums for this dust class. The maximum degree of permeability is 0.1% and the disposal must be low dust. Dust Class H (high). The dusts which belong to this class are: dusts with OEL values1), all carcinogenic dusts and dusts which are mixed with pathogenic agents.
ATTIX 995-0H/M SD XC Type 22 in the room must be adequate if the exhaust air from the vacuum cleaner is blown into the room (please observe regulations valid in your country). The appliance is suitable for commercial use, such as e.g. in • Hotels, Schools, Hospitals, Factories, Shops, Offices, Hire shops Any other use is considered as improper use. The manufacturer accepts no liability for any damage resulting from such use. The risk for such use is borne solely by the user.
ATTIX 995-0H/M SD XC Type 22 Maintenance, cleaning and repair During the following work, ensure that dust is not unnecessarily spread around. Wear a P2 breathing mask. Only carry out maintenance work described in the operating instructions. Always pull out the mains plug before cleaning and maintenance of the vacuum cleaner. During maintenance and cleaning, handle the vacuum cleaner in such a manner that there is no danger for maintenance staff or other persons. In the maintenance area 1.
ATTIX 995-0H/M SD XC Type 22 Risks Electrical components DANGER Electric shock due to faulty mains connecting lead. Touching a faulty mains connecting lead can result in serious or even fatal injuries. 1. Do not damage the mains power lead (e.g. by driving over it, pulling or crushing it). 2. Regularly check whether the power cord is damaged or shows signs of ageing. 3.
ATTIX 995-0H/M SD XC Type 22 Hazardous materials WARNING Hazardous materials. Vacuuming up hazardous materials can lead to serious or even fatal injuries. 1. The following materials must not be picked up by the vacuum cleaner: - hot materials (burning cigarettes, hot ash, etc.) - flammable, explosive, aggressive liquids (e.g. petrol, solvents, acids, alkalis, etc.
ATTIX 995-0H/M SD XC Type 22 Spare parts and accessories CAUTION Spare parts and accessories. For picking up flammable dust in Zone 22: Only use accessories which are certified by the manufacturer of the Type 22 machine. The use of other accessories can cause danger of explosion. The use of non-genuine spare parts and accessories can impair the safety of the appliance. 1. Only use spare parts and accessories from Nilfisk-Alto. 2.
ATTIX 995-0H/M SD XC Type 22 2 Description 2.
ATTIX 995-0H/M SD XC Type 22 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 2.
ATTIX 995-0H/M SD XC Type 22 3 Before starting the cleaner 3.1 Assembling the vacuum cleaner 3.1.1 Taking accessories out of the packaging 1. Take vacuum cleaner and accessories out of the packaging. 2. The mains plug should not yet be inserted into a socket. 3. Apply parking brakes (A) on both castors. A A B B 4. Open the retaining clamps (B) and remove the upper section of the vacuum cleaner. 5. Take the accessories (C) out of the dirt tank and the packaging.
ATTIX 995-0H/M SD XC Type 22 3.1.2 Before starting the cleaner Depending on how hazardous the dust is, the cleaner must be fitted with appropriate filters: Type of dust Filter bag/waste bag • Non-hazardous dust • Non-carcinogenic dust with OEL values >0.1 mg/m³ (observe any additional national regulations) • Wood dust • Explosive dust, dust explosion class St1, St2, St3 in Zone 22 Waste bag (5 pcs.) Order No.
ATTIX 995-0H/M SD XC Type 22 B 3. Swing the bar (B) upwards. 4. Use the handle (C) to pull the dirt tank out of the vacuum cleaner. C D 5. Insert the safety filter bag (D) in the dirt tank. 6. Fold the top edge of the disposal bag over the rim of the dirt tank. 7. Push the dirt tank as far as possible into the vacuum cleaner. 8. Swing the bar (B) downwards without forcing it. C B 9. Close (top) inlet with fitting plug "M" (E).
ATTIX 995-0H/M SD XC Type 22 10.Connect suction hose to inlet fitting "H" (down) (F). F 3.1.4 Inserting the disposal bag 1. The mains plug should not yet be inserted into a socket. 2. Apply parking brakes (A) on both castors. A A B 3. Swing the bar (B) upwards. 4. Use the handle (C) to pull the dirt tank out of the vacuum cleaner. C 5. Insert the disposal bag (D) in the dirt tank. 6. Fold the top edge of the disposal bag over the rim of the dirt tank.
ATTIX 995-0H/M SD XC Type 22 7. Push the dirt tank as far as possible into the vacuum cleaner. 8. Swing the bar (B) downwards without forcing it. C B 9. Close (down) inlet with fitting plug "H" (E). E F 1) Optional accessories / Option depending on model Original Instructions 10.Connect suction hose to inlet fitting "M" (top) (F).
ATTIX 995-0H/M SD XC Type 22 4 Operation 4.1 Connections 4.1.1 Electrical connection 1. Ensure that the cleaner is switched off. 2. Insert the power cord into a properly installed and fused socket with earthing contact. The operating voltage shown on the rating plate must correspond to the voltage of the mains power supply. 4.2 Switching on the vacuum cleaner 4.2.1 Switch „ I-0-II “ The hose diameter and the setting for the suction hose diameter must correspond. ø27 ø32 ø36 ø38 ø50 4.
ATTIX 995-0H/M SD XC Type 22 4.5 Cleaning the filter element Only for vacuum cleaning without a cloth insert filter. 10 sec . To ensure that suction performance is always at its best, the filter element is automatically cleaned during operation. We recommend complete cleaning if the filter element becomes extremely dirty. 1. Switch off the vacuum cleaner 2. Close the nozzles or suction hose opening with the palm of your hand. 3. Turn the switch to position „I“ and let the cleaner operate for approx.
ATTIX 995-0H/M SD XC Type 22 5 Applications and techniques 5.1 Techniques If used correctly, additional accessories, suction nozzles and suction hoses can enhance the cleaning action and reduce the cleaning effort. Effective cleaning is achieved if you follow just a few guidelines in combination with your own practical experience in special fields. Here are some basic tips. 5.1.
ATTIX 995-0H/M SD XC Type 22 6 After finishing work 6.1 Switching the vacuum cleaner off and storage ø ø 3 ø6 27 32 ø 5 0 1) Optional accessories / Option depending on model Original Instructions 1. After picking up hazardous dust, vacuum clean the outside of the cleaner. 2. Switch off the vacuum cleaner and pull the mains plug out of the socket. 3. Make sure that both plugs are inserted in fittings. 4. Wind up the power cord and hang it on the handle. 5.
ATTIX 995-0H/M SD XC Type 22 7 Maintenance 7.1 Maintenance plan When replacing the filter bag, waste bag or filter element After finishing work When required 7.2.1 Check the antistatic clamps 7.2.2 Emptying the dirt tank 7.2.3 Replacing the disposal bag 7.2.4 Replacing the safety filter bag 7.2.5 Replacing the filter element "H" 7.2.6 Replacing the filter for air supply to motor 7.2 Maintenance work 7.2.1 Check the antistatic clamps 1.
ATTIX 995-0H/M SD XC Type 22 7.2.2 Emptying the dirt tank 1. Switch off the vacuum cleaner and pull the mains plug out of the socket. 2. Apply parking brakes (A) on both castors. A A B C D E 1) Optional accessories / Option depending on model Original Instructions Removing the dirt tank: 3. Swing the bar (B) upwards. 4. Use the handle (C) to pull the dirt tank out of the vacuum cleaner. 5. Tipping out the collected dirt: WARNING! If heavy dirt has been picked up, never lift the dirt tank alone.
ATTIX 995-0H/M SD XC Type 22 7.2.3 Replacing the disposal bag 1. Switch off the vacuum cleaner and pull the mains plug out of the socket. 2. Apply parking brakes (A) on both castors. A Removing the disposal bag: 3. Swing the bar (B) upwards. 4. Use the handle (C) to pull the dirt tank out of the vacuum cleaner. 5. Close the disposal bag with string (D) and remove it from the dirt tank. WARNING! If heavy dirt has been picked up, never lift the dirt tank alone.
ATTIX 995-0H/M SD XC Type 22 7.2.4 Replacing the safety filter bag During the following work, ensure that dust is not unnecessarily spread around. Wear a P2 breathing mask. 1. Switch off the vacuum cleaner and pull the mains plug out of the socket. 2. Apply parking brakes (A) on both castors. A Removing the safety filter bag: 3. Swing the bar (B) upwards. 4. Use the handle (C) to pull the dirt tank out of the vacuum cleaner. 5. Close the disposal bag with string (D) and remove it from the dirt tank.
ATTIX 995-0H/M SD XC Type 22 7.2.5 Replacing the filter element "H" During the following work, ensure that dust is not unnecessarily spread around. Wear a P2 breathing mask. 1. Switch off the vacuum cleaner and pull the mains plug out of the socket. 2. Apply parking brakes (A) on both castors. A A Never use the vacuum cleaner without a filter. B B D C 3. Open the retaining clamps (B) and remove the upper section of the vacuum cleaner. Remove the filter element: 4.
ATTIX 995-0H/M SD XC Type 22 8. Carefully remove the filter element and close the protective filter bag with a knot. E F G D C 7.2.6 Replacing the filter for air suppy to motor During the following work, ensure that dust is not unnecessarily spread around. Wear a P2 breathing mask. Never use the vacuum cleaner without a filter. 1) Optional accessories / Option depending on model Original Instructions B A Inserting the filter element: 9. Clean the filter seal (F).
ATTIX 995-0H/M SD XC Type 22 8 Troubleshooting Fault ‡ Motor does not start ‡ The acoustic warning sounds. (Reduced suction power) Cause Remedy > Fuse of the mains socket has blown. • Connect mains fuse. > Overload protection switch has tripped. • Switch off the vacuum cleaner and allow it to cool for approx. 5 minutes. If the cleaner cannot be started again, contact the Nilfisk-Alto service department. > Motor is faulty. • Have motor changed by Nilfisk-Alto Service.
ATTIX 995-0H/M SD XC Type 22 9 Further information 9.1 Recycling the vacuum cleaner Make the old cleaner unusable immediately: 1. Unplug the cleaner 2. Cut the power cord. 3. Do not discard of electrical appliances with household waste. As specified in European Directive 2002/96/EC on old electrical and electronic appliances, used electrical goods must be collected separately and recycled ecologically. Contact your local authorities or your nearest dealer for further information. 9.
ATTIX 995-0H/M SD XC Type 22 9.
http://www.nilfisk-advance.com HEAD QUARTER DENMARK Nilfisk-Advance Group Sognevej 25 DK-2605 Brøndby Tel.: (+45) 4323 8100 E-mail: mail.com@nilfisk-advance.com SALES COMPANIES ARGENTINA Nilfisk-Advance srl. Edificio Central Park Herrera 1855, Office 604 Ciudad Autónoma de Buenos Aires Tel.: (+54) 11 6091 1571 AUSTRALIA Nilfisk-Advance 48 Egerton St. P.O. Box 6046 Silverwater, N.S.W. 2128 Tel.: +61 2 8748 5900 E-mail: info@nilfisk-advance.com.