Operating instructions ATTIX 961-01 ATTIX 963-21 ED XC ATTIX 965-21 SD XC 107401235 E
ATTIX 9 STD Contents 1 Important safety instructions ............................................................................................2 2 Description 2.1 2.2 Operating elements ..............................................................6 Operating panel ....................................................................7 3 Before starting the cleaner 3.1 3.1.1 3.1.2 3.1.3 3.1.4 3.1.5 Assembling the vacuum cleaner...........................................
ATTIX 9 STD 1 Important safety instructions Symbols used to mark instructions Prior to using the appliance for the first time, be sure to read this document through and keep it ready to hand. DANGER Danger that leads directly to serious or irreversible injuries, or even death. WARNING Danger that can lead to serious injuries or even death. CAUTION Danger that can lead to minor injuries and damage.
ATTIX 9 STD Any other use is considered as improper use. The manufacturer accepts no liability for any damage resulting from such use. The risk for such use is borne solely by the user. Proper use also includes proper operation, servicing and repairs as specified by the manufacturer. Transport 1. Before transporting the dirt tank, close all the locks. 2. Do not tilt the cleaner if there is liquid in the dirt tank. 3. Do not use a crane hook to lift the cleaner. Storage 1.
ATTIX 9 STD Risks Electrical components DANGER Electric shock due to faulty mains connecting lead. Touching a faulty mains connecting lead can result in serious or even fatal injuries. 1. Do not damage the mains power lead (e.g. by driving over it, pulling or crushing it). 2. Regularly check whether the power cord is damaged or shows signs of ageing. 3.
ATTIX 9 STD Picking up liquids CAUTION Picking up liquids. ATTIX 965-21 SD XC: Due to their construction vacuum cleaners with a removable tank (SD) do not have an automatic level indicator. There is a risk of damage to the vacuum cleaner due to overfilling or of damage due to leakage of the picked up liquid. 1. Never pick up more than 40 litres at once. 2. Switch off the vacuum cleaner and empty the dirt tank. Hazardous materials WARNING Hazardous materials.
ATTIX 9 STD 2 Description 2.
ATTIX 9 STD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 2.
ATTIX 9 STD 3 Before starting the cleaner 3.1 Assembling the vacuum cleaner 3.1.1 Taking accessories out of the packaging 1. Take vacuum cleaner and accessories out of the packaging. 2. The mains plug should not yet be inserted into a socket. 3. Apply parking brakes (A) on both castors. A A B 4. Open the retaining clamps (B) and remove the upper section of the vacuum cleaner. 5. Take the accessories 1) out of the dirt tank and the packaging. B 3.1.
ATTIX 9 STD 3.1.3 Inserting the filter bag (ATTIX 961-01) 1. The mains plug should not yet be inserted into a socket. 2. Apply parking brakes (A) on both castors. A A B B 3. Open the retaining clamps (B) and remove the upper section of the vacuum cleaner. 4. Insert the filter bag (C) in the dirt tank. B 1) Optional accessories / Option depending on model Original Instructions B 5. Attach the upper section of the vacuum cleaner. 6. Close the retaining clamps (B).
ATTIX 9 STD 3.1.4 Inserting the disposal bag (ATTIX 965-21 SD XC) 1. The mains plug should not yet be inserted into a socket. 2. Apply parking brakes (A) on both castors. A A B 3. Swing the bar (B) upwards. 4. Use the handle (C) to pull the dirt tank out of the vacuum cleaner. C 5. Insert the disposal bag (D) in the dirt tank. 6. Fold the top edge of the disposal bag over the rim of the dirt tank. D 7. Push the dirt tank as far as possible into the vacuum cleaner. 8.
ATTIX 9 STD 3.1.5 Inserting the disposal bag (ATTIX 963-21 ED XC) 1. The mains plug should not yet be inserted into a socket. 2. Apply parking brakes (A) on both castors. 3. Open clamping ring (B). B A A 4. Insert disposal bag (C) into clamping ring. 5. Fold the top edge of the disposal bag over the rim of the clamping ring. C D 6. Attach the new disposal bag (C) onto the storage container (D). C 7. Close clamping ring (B).
ATTIX 9 STD 4 Control / Operation 4.1 Connections 4.1.1 Connecting the suction hose 1. Connect the suction hose. 4.1.2 Electrical connection 1. Ensure that the cleaner is switched off. 2. Insert the power cord into a properly installed and fused socket with earthing contact. The operating voltage shown on the rating plate must correspond to the voltage of the mains power supply. 4.2 Switching on the vacuum cleaner 4.2.1 Switch " I-0-II " 1) 4.2.
ATTIX 9 STD 4.2.3 Suction power control 1) Switch position Function The suction power control switch allows precise adaptation of the suction power for different cleaning tasks. 4.2.4 Auto-On/Off-Operation - "auto" switch position 1) The vacuum cleaner is switched on and off by the power tool connected. Dirt is picked up from the source of dust immediately. To comply with regulations, only approved dust producing tools should be connected.
ATTIX 9 STD 4.3 Cleaning the filter element 4.3.1 Cleaning the filter element (Push&Clean System)1) Only for vacuum cleaning without a filter bag and without a cloth insert filter. If suction performance drops: 1. Turn switch to position "II" (maximum suction power). 2. Close the nozzles or suction hose opening with the palm of your hand. 3. Press the button to start filter cleaning three times. The resulting stream of air removes attached dust from the slats of the filter elements. 4.3.
ATTIX 9 STD 5 Applications and techniques 5.1 Techniques If used correctly, additional accessories, suction nozzles and suction hoses can enhance the cleaning action and reduce the cleaning effort. Effective cleaning is achieved if you follow just a few guidelines in combination with your own practical experience in special fields. Here are some basic tips. 5.1.1 Picking up dry substances CAUTION! Do not pick up flammable substances.
ATTIX 9 STD 6 After finishing work 6.1 Switching the vacuum cleaner off and storage 1. Switch off the cleaner and pull the mains plug out of the socket. 2. Wind up the power cord and hang it on the handle (A). Begin winding up the cord at the cleaner end and not the plug end to prevent the power cord from tangling up. 3. Empty the dirt tank and clean the vacuum cleaner. 4. After picking up liquids: Store the upper section of the vacuum cleaner separately so that the filter element can dry. 5.
ATTIX 9 STD 7 Maintenance 7.1 Maintenance plan ATTIX 961-01: After finishing work When required 7.2.1 Emptying dirt tank 7.2.3 Replacing the filter bag 7.2.6 Replacing filter element ATTIX 965-21 SD XC: After finishing work When required 7.2.2 Emptying dirt tank 7.2.4 Replacing the disposal bag 7.2.6 Replacing filter element ATTIX 963-21 ED XC: After finishing work When required 7.2.5 Replacing the disposal bag 7.2.
ATTIX 9 STD 7.2 Maintenance work 7.2.1 Emptying the dirt tank (ATTIX 961-01) After emptying the tank: clean the rim of the tank and the seals in the intermediate ring and the upper section of cleaner before refitting them. If the seal or groove is dirty or damaged, the suction performance will be reduced. Before reinserting the suction hose: clean the inlet fitting and hose collar. 1. Switch off the vacuum cleaner and pull the mains plug out of the socket. 2. Apply parking brakes (A) on both castors.
ATTIX 9 STD 7.2.2 Emptying the dirt tank (ATTIX 965-21 SD XC) 1. Switch off the vacuum cleaner and pull the mains plug out of the socket. 2. Apply parking brakes (A) on both castors. A A B C D E 1) Optional accessories / Option depending on model Original Instructions Removing the dirt tank: 3. Swing the bar (B) upwards. 4. Use the handle (C) to pull the dirt tank out of the vacuum cleaner. 5. Tipping out the collected dirt: WARNING! If heavy dirt has been picked up, never lift the dirt tank alone.
ATTIX 9 STD 7.2.3 Replacing the filter bag (ATTIX 961-01) 1. Switch off the vacuum cleaner and pull the mains plug out of the socket. 2. Apply parking brakes (A) on both castors. A A If the filter bag has heavy dirt, remove the bag by tilting the tank. See Section 7.2.1. B B Removing the filter bag: 4. Carefully remove the filter bag connection from the inlet fitting (C). 5. Close the filter bag connection (1) with the hinged lid. 6. Dispose of the filter bag in accordance with legal regulations.
ATTIX 9 STD 7.2.4 Replacing the disposal bag (ATTIX 965-21 SD XC) 1. Switch off the vacuum cleaner and pull the mains plug out of the socket. 2. Apply parking brakes (A) on both castors. A A B D C E G F B 1) Optional accessories / Option depending on model Original Instructions Removing the disposal bag: 3. Swing the bar (B) upwards. 4. Use the handle (C) to pull the dirt tank out of the vacuum cleaner. 5. Close the disposal bag with string (D) and remove it from the dirt tank.
ATTIX 9 STD 7.2.5 Replacing the disposal bag (ATTIX 963-21 ED XC) 1. Switch off the vacuum cleaner and pull the mains plug out of the socket. 2. Apply parking brakes (A) on both castors. A A Remove the disposal bag: 3. Open clamping ring (B). 4. Detach the disposal bag (C) from the storage container and seal it. 5. Dispose of the dirt in accordance with legal regulations. B C Inserting the disposal bag: 1. Insert disposal bag (C) into clamping ring. 2.
ATTIX 9 STD 7.2.6 Replacing filter element 1. Switch off the vacuum cleaner and pull the mains plug out of the socket. 2. Apply parking brakes (A) on both castors. Never use the vacuum cleaner without a filter. A A B B Removing the filter element: 4. Lay the upper section of the cleaner down with the filter element facing upwards. 5. Open the bar handle (C) and remove it. 6. Remove the filter holder (D). 7. Carefully remove the filter element (E). 8.
ATTIX 9 STD 8 Troubleshooting Fault ‡ Motor does not start Cause Remedy > Fuse of the mains socket has blown. • Connect mains fuse. > Overload protection switch has tripped. • Switch off the vacuum cleaner and allow it to cool for approx. 5 minutes. If the cleaner cannot be started again, contact the Alto service department. > Motor is faulty. • Have motor changed by Nilfisk-Alto Service. > Power tool/pneumatic tool is defective or not connected properly.
ATTIX 9 STD 9 Further information 9.1 1. Make the old cleaner unusable immediately. 2. Unplug the cleaner and cut the power cord. 3. Do not discard of electrical appliances with household waste. Recycling the vacuum cleaner As specified in European Directive 2002/96/EC on old electrical and electronic appliances, used electrical goods must be collected separately and recycled ecologically. Contact your local authorities or your nearest dealer for further information. 9.
ATTIX 9 STD 9.
HEAD QUARTER DENMARK Nilfisk-Advance A/S Sognevej 25 DK-2605 Brøndby Tel.: (+45) 4323 8100 www.nilfisk-advance.com SALES COMPANIES ARGENTINA Nilfisk-Advance srl. Herrera 1855, 6 floor, Of. A-604 ZC 1293 – Ciudad Autónoma de Buenos Aires – Argentina www.nilfisk-alto.com AUSTRALIA Nilfisk-ALTO Unit 1, 13 Bessemer Street Blacktown NSW 2148 Australia www.nilfisk-alto.com.au AUSTRIA Nilfisk-ALTO Geschäftsbereich der Nilfisk-Advance GmbH Metzgerstraße 68 A-5101 Bergheim/Salzburg www.nilfisk-alto.