Meaning
of
address
30 flag data (different from old type CPU)
128
:
Power voltage falls below DC/DC converter guaranteed voltage level.
64 : Closing curtain SWfails to turn on even if closing curtain Mg turns off.
8 : Mechanical pulse fails to be output 255ms during charging.
4 : X contact is closed without T setting.
2 : Correct pulses are not output while aperture control is carried.
1 : 40
m
more aperture pulses are generated after aperture Mg turns on.
If the above number is writen in the address 30 of EEPROM, it means
that the mentioned trouble happened in the camera. If two
or more
troubles have happened, added number is
shown.
For example, If the
number in address 30 is 192, troubles mentioned in
’128
and 64” in
the past.
Note : 1. If the shutter is released while depth-of-field oreview button is
depressed, the number
‘2”
is written in address 30. The actual
trouble did not necessarily occur.
2.
After
rewi
r, be
sure to change the number in address
30
to
* EEPROM list of Malti Photomic Finder
0:
1:
2:
3:
4:
5:
6:
7:
Note :
Compensattion value at center (five-part SPD) l/8EV per lLSB
Compensattion value at upper-left (five-part
SPD)
l/8EV per lLSB
Compensate ion value at upper-right (f ive-part SPD)
l/8EV per lLSB
Compensattion value at lower-left (five-part SPD) l/8EV per lLSB
Compensattion value at lower-right (f ive-part
SPD) l/8EV per lLSB
Not in use.
Not in use.
Not in use.
If a customer request You to change the meter characteristic to over or
under exposure, change the value in address O to
4
by the same degree.
2/2