7. Required equipment and conditions
AC adapter EH-5 and USB cable (mini B type) UC-E4 are used for all adjustments so they are not
specied in the list.
Item Required device Setting/Remarks
1
Sensitivity adjustment
5100K color viewer   J63070
ex-model viewer J63049 is also
available.)
Luminance meter BM-3000   
J63068
Tool lensto x aperture J61185
ND lter
 ND8×1+ND4×2
Equivalent to luminance LV13
Aperture F8
52 mm,5-step light reduction; Use
the packaged product
2
Gr/Gb compensation
adjustment (R/B lter)
5100K color viewer   J63070
ex-model viewer J63049 is also
available.)
Luminance meter BM-3000  
J63068
Tool lensFixed aperture J61185
SP3 (R lter)  J63087
SP1 (B lter J63085
Equivalent to luminance LV13
Aperture F5.6
3
Sensitivity ratio adjustment
5100K color viewer   J63070
ex-model viewer J63049 is also
available.)
Luminance meter BM-3000  
J63068
Tool lensto x aperture J61185
Equivalent to luminance LV13
Aperture F8; No lter
4
Gr/Gb compensation
inspection (No lter)
5100K color viewer   J63070
ex-model viewer J63049 is also
available.)
Luminance meter BM-3000  
J63068
Tool lensto x aperture J61185
Equivalent to luminance LV13
Aperture F5.6; No lter
5
CCD black point defect
compensation
5100K color viewer   J63070
ex-model viewer J63049 is also
available.)
Luminance meter BM-3000  
J63068
Tool lensto x aperture J61185
Equivalent to luminance LV13
Aperture F5.6
6
CCD white point defect
compensation
Body cap or lens cap Environmental temperature
approx. 20 - 25
7
Sensitivity, sensitivity ratio
reference value calculation
Same as "Sensitivity adjustment" No lter when sensitivity ratio
reference value is calculated.
8
TFT angle of view adjustment None Only for NTSC (unnecessary for
PAL)
9
Reading of RISC version None
New established tool