User Guide
- A49 ・ -
VBA12001-R.3668.A
#5692
#5697
#5677×7
Bottom cover
・
Attach the bottom cover with the screw
(
#5692), the screw
(
#5697), and 7 screws
(
#5677).
Bottom cover
・
Replace the nder screen with the innity focus check screen (J15410), and use the reference lens (J18010)
and read the value. In case it is out of standard, increase or decrease washers (#297A or#297B) for
adjustments. * Supply the power (Battery or EH-5) for checking.
∞ Innity alignment & adjustment
Reference
line
"0" position
J18010
Standard:
±0.07mm
(
1 scale
=
0.01mm
)
Value of J18010 Adjustment
+0.07
~
-0.07 Adjustment unnecessary if within standard
+0.08
~
+0.15 Decrease washers (#297) (for thinning)
-0.08
~
-0.15 Increase washers (#297) (for thickening)
+0.15 or more; -0.15 or less Check if Front body or Penta box is not
deformed.