User Guide

- A27 -
VBA12001-R.3668.A
Procedure
To prevent short circuit, attach the grip (#26) with the screw (#635), and
also I/F cover (#B5028) with the screws (#635). Insert
AECCD alignment tool (J15417)
between the FD screen and the SI plate.
Position AE-CCD positioning tool in the direction of the arrow to
insert.
② 
Connect camera and PC via USB cable UC-E4.
   
  
③ 
Provide power to camera via AC adapter EH-5.
Note: Be careful of short circuit where there is no cover.
④ 
Start up the inspection and adjustment software for D50 (J18385),
and select "INSPECTION AND ADJUSTMENT FOR AECCD
POSITION" then "CCD ALIGNMENT INSPECTION AND
ADJUSTMENT".
  
Cover the camera with black cloth, when measured.
By following instructions on PC, make the position adjustment of
AECCD by the screws (#291 a,b).
Select “CCD SLANT INSPECTION” of the adjustment software and
make an inspection.
After the adjustment, x the AECCD by applying Crazy glue slightly..
Remove EH-5, UC-E4, and AECCD positioning tool(J15417).
Take out the grip (#26), and I/F cover unit (#B5028).
Adhesive: Super glue
Reference screw
b:#291
AE-CCD positioning
tool (J15417)
Atach the metering FPC unit
slightly with 3 screws (#291).
Give the reference screw 1
turn counterclockwise, then
make an adjustment by the
screws (a and b).
Note:
With the metering FPC unit being
attached slightly, if more than 3
turns are given to loose, the head
of the screws touch the top cover.
Inspection and adjustment of AE CCD Alignment
Meterring FPC unit
a:#291