3. Front Body
Take out 3 screws (#291) to remove the metering FPC unit (#B2008).
3 springs (#290) come off.
Take out 2 screws (#635) to remove the metering FPC-base unit (#B286).
Remove the tape (#796).
Take out the screw (#635) to remove the eyepiece-lens unit (#B261).
Note:
The screws (#291) are attached with the
adhesive.
In case they (#291) are moved, AE CCD
position adjustment (ref. Assembly) becomes
necessary.
#796
 
Eyepiece unit
 
Metering FPC unit
#291×3
#290×3
#635×2
#B286
#B2008
#635×2