11-9-2 Contact discharge (without cover case)
Immunity level: +/- 8kV by 150pF / 330 ohms
It discharges 25 times per every electrical polarity (+/-) to the gate in the front face,
the knob of the top cover, and the card transportation knob.
This test is done while non-operating (power off).
The device should operate normally after powered on.
11-9-3 Contact discharge (with cover case)
Immunity level: +/- 6kV by 150pF / 330 ohms
It discharges 10 times per every electrical polarity (+/-) to the metal part that can be
touched from the outside.
Unrecoverable error does not be occurred during operation. The phenomenon that
automatically returns to normal operation is permitted.
11-10 Radiated, Radio-frequency, electromagnetic field immunity test
Reference document: EN/IEC 61000-4-3
Immunity level: 3V/m
11-11 Electrical fast transient/burst immunity test
Reference document: EN/IEC 61000-4-4
Immunity level: +/- 0.5kV
11-12 Immunity to conducted disturbance, induced by radio-frequency fields
Reference document: EN/IEC 61000-4- 6
Immunity level: 3V
11-13 Power frequency magnetic field immunity test
Reference document: EN/IEC 61000-4-8
Immunity level: 1A/m
11-14 Thermal shock
-10 degrees C / +60 degrees C
This test is done 10 cycles. One cycle requires one hour.
The device should operate normally after returned room temperature.