User's Manual
No ASR – NP – 26819 – 01
12
CONFIDENTIAL
11-5 Mechanical shock test
Without packing:
Test method: Fixing at the end and drop down at another end
Lift up angle: 30 degrees
Lift up edge: Every 4 side
Number of time: 2 times per one side
Table situation: On the wood table
This test is done under non-operating.
With packing:
Test method: Free fall
Lift up height: 600 mm
Falling direction: 1 corner, 3 ridges and 6 faces
Total falling times: 10 times
There is no degradation.
11-6 Attitude
Horizontal Attitude (Within +/- 5 degrees)
The device does not turn over in 15 degrees attitude.
11-7 USB Cable strength of scanner unit
The USB cable does not break when it is applied force of 60N (6.12 kgf ).
11-8 Radiated and Conducted Emissions
Reference document: EN55022 Class B
FCC Part 15 B、FCC Part 15 C
11-9 Electrostatic discharge immunity test
11-9-1 Aerial discharge(with cover case)
Immunity level: +/- 10kV by 150pF / 330 ohms
It discharges 25 times per every electrical polarity (+/-) to the gate in the front face.
Unrecoverable error does not be occurred during operation. The phenomenon that
automatically returns to normal operation is permitted.
B