User's Manual

No ASR NP 26819 01
11
CONFIDENTIAL
11-2 Operating condition
Operating:
+0 degrees C ~ 40 degrees C
30%~85% R.H no condensation
Maximum wet bulb is +30 degrees C
No warped card when temperature is between 0~+5 degrees C.
Non-operating (power off):
-10 degrees C~ 60 degrees C
20%~85% R.H
No condensation
Maximum wet bulb is +35 degrees C
11-3 Transport condition
Packed:
-10 degrees C ~ 60 degrees C
10%~90% R.H
No condensation
Maximum wet bulb is +40 degrees C
Judgment by the test:
There is no functional error after 12 hours since the device is return to operating
condition.
11-4 Vibration Test
Operating: Vibration frequency: 5~50 Hz
Acceleration: 2.0 m/seconds
2
(0.2G) Constant
Sweep: Logarithmic change
Sweep time: 1minute / octave
5-50-5 Hz repeats, 10 minutes
Total testing time:0.5 hour (x, y, z every direction)
No abnormality is seen electrically and mechanically when the device is in use.
Non-operating (power off): Vibration frequency: 5~50 Hz
Acceleration: 4.0 m/seconds
2
(0.4G) constant
Maximum peak acceleration 30 m/secons
2
(3.0G)
Sweep: Logarithmic change
Sweep time: 1 minute / octave
5-50-5Hz repeats, 10 minutes
Total testing time: 0.5 hour (x, y, z every direction)
There is no functional error after vibration testing.