User's Manual
No ASR – NP – 20847 – 01
8
5-8-4. Mechanical shock characteristic
Without packing:
Test method: Fixing at the end and drop down at another end
Lift up angle: 30 degrees
Lift up edge: Every 4 side
Number of time: 2 times per one side
Table situation: On the wood table
This test is done under none operating.
With packing:
Test method: Free fall
Lift up height: 600 mm
Falling direction: 1 corner, 3 ridges and 6 faces
Total falling times: 10 times
There is no degradation.
5-8-5. Attitude
Horizontal Attitude (Within +/- 5 degrees)
The device does not turn over in 15 degrees attitude.
5-8-7. Cable strength
The power cord does not break when it is applied force of 15.9 kgf (156N)
in all directions.
5-8-8. Electrostatic discharge immunity
5-8-8-1. Aerial discharge (with cover case): +/- 10kV by 150pF / 330 ohms
It discharges 10 times per every electrical polarity (+/-) to the fixation
screw that is on the rear of cover case and the gate in the front face.
Unrecoverable error does not be occurred during operation. The
phenomenon that automatically returns to normal operation is permitted.
5-8-8-2. Contact discharge (without cover case): +/- 8kV by 150pF / 330 ohms
It discharges 25 times per every electrical polarity (+/-) to the metallic
parts that appear when the cover case is removed.
This test is done while non-operating.
The device should operate normally after powered on.
5-8-9. Electrical fast transient/burst immunity test (IEC61000-4-4)
This test is done while operated. The phenomenon that automatically
returns to normal operation is permitted.