Specification
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393
www.nicorlighting.com November 15, 2019 2:46 PM NUC5 Page 2 of 4
Photometric Data
NUC5 2700K 8”
Input Voltage (VAC) 120
System Level Power (W) 3.63
Delivered Lumens (Lm) 247
System Ecacy (Lm/W) 67.9
Correlated Color Temp (K) 2755
Color Rendering Index (CRI) 93
Beam Angle
106
NUC5 2700K 12”
Input Voltage (VAC) 120
System Level Power (W) 5.25
Delivered Lumens (Lm) 381
System Ecacy (Lm/W) 72.6
Correlated Color Temp (K) 2736
Color Rendering Index (CRI) 92
Beam Angle
108
NUC5 2700K 21”
Input Voltage (VAC) 120
System Level Power (W) 8.66
Delivered Lumens (Lm) 632
System Ecacy (Lm/W) 73.0
Correlated Color Temp (K) 2747
Color Rendering Index (CRI) 92
Beam Angle
107
Zonal Lumen Summary
Zone Lumens % of Luminaire
0-30
71 29.5%
0-40
115 47.9%
0-60
198 82.6%
0-90
239 100%
90-180
0 0%
0-180
239 100%
Zonal Lumen Summary
Zone Lumens % of Luminaire
0-30
71 29.5%
0-40
115 47.9%
0-60
198 82.6%
0-90
239 100%
90-180
0 0%
0-180
239 100%
Zonal Lumen Summary
Zone Lumens % of Luminaire
0-30
176 29.1%
0-40
287 47.3%
0-60
497 82.0%
0-90
607 100%
90-180
0 0%
0-180
607 100%
Cone of Light Tabulation
Mounted height
(Inches)
Footcandles
Beam Center
Diameter
(Inches)
12
91.9 31.3
18
40.9 47.0
24
23.0 62.7
30
14.7 78.3
36
10.2 94.0
Cone of Light Tabulation
Mounted height
(Inches)
Footcandles
Beam Center
Diameter
(Inches)
12
137.7 32.4
18
61.2 48.6
24
34.4 64.8
30
22.0 80.9
36
15.3 97.1
Cone of Light Tabulation
Mounted height
(Inches)
Footcandles
Beam Center
Diameter
(Inches)
12
229.6 32.4
18
102.0 48.7
24
57.4 64.9
30
36.7 81.1
36
25.5 97.3
Intensity Summary
(Candle Power)
Angle Mean CP
0 1242
10 1220.3
20 1141.6
30 1020.6
40 872.1
50 698.6
60 515.8
70 344.4
80 176.7
90 2.1
Intensity Summary
(Candle Power)
Angle Mean CP
0
138
10
135
20
127
30
115
40
99
50
79
60
56
70
31
80
9
90
0
Intensity Summary
(Candle Power)
Angle Mean CP
0
230
10
225
20
212
30
191
40
163
50
130
60
93
70
52
80
16
90
0
Fixture tested per LM-79-08. Photometric data is of the performance of a
representative xture. Results may vary in the eld.
Fixture tested per LM-79-08. Photometric data is of the performance of a
representative xture. Results may vary in the eld.
Fixture tested per LM-79-08. Photometric data is of the performance of a
representative xture. Results may vary in the eld.
CCT Data Multiplier
NUC508S30 1.12
NUC508S40 1.17
CCT Data Multiplier
NUC512S30 1.12
NUC512S40 1.17
CCT Data Multiplier
NUC521S30 1.12
NUC521S40 1.17
23
46
69
92
35
69
104
139
58
115
173
231