NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com November 20, 2019 9:23 AM
STW Wet Location LED Step Light
INSTALLATION INSTRUCTIONS
Model: STW11203KV, STW11203KH
What’s In The Box
One (1) STW
One (1) Mounting Kit
WARNING
- Risk of re or electric shock. LED installation requires knowledge of luminaires electrical systems. Review the diagrams thoroughly
before beginning. All electrical connections must be in accordance with local codes, ordinances, and the National Electric Code. If not
qualied, do not attempt installation. Contact a qualied licensed electrician.
- Before installation, disconnect the power by turning o the circuit breaker or by removing the appropriate fuse at the fuse box. Using
the light switch to turn power o is not sucient to prevent electrical shock.
- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects
- All parts must be used as indicated in the instructions.
- The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
- To maintain Wet Location Rating, ONLY use UL approved wet location junction boxes and conduit.
Tools Needed
A Phillips screwdriver will be needed to install the STW.
Secure the mounting bracket to the junction box, using the
two (2) 8-32 junction screws provided.
Note:
For outdoor mounting or wet location it is required to use
clear, outdoor-rated silicone caulk between the gasket and
the mounting surface. Use a water-tight junction box, ensure
it is properly sealed.
3
Connect the xture input wires using the provided wire nuts.
Wiring:
Black - 120 Vac Line
White - 120 Vac Neutral
Green/Yellow Ground
Make sure all power is turned o before beginning installation
Using the rubber washers and mounting screws, secure the
xture to the mounting bracket.
5
Carefully unpack the step light from its packaging. Inspect product for defects due to shipping.
1
Installing the STW
2
Tuck wiring connections into the junction box, behind the mounting bracket.
4
Junction Box Dimensions*
STW ts into 2” x 4” Junction Box
Minimum Dimensions
Vertical Model: 2.9” L x 1.85” W x 1.85” H
Horizontal Model*: 2.9” x 2” W x 1.85 H
*Horizontal Model may not t all metallic junction boxes