Installation Instructions

ENGLISH – 5
3. On the OLD transmitter, press and hold any button, within the
desired sector, until LED (B) of the NEW transmitter switches
on. Subsequently, release the button (LED (B) of the NEW trans
-
mitter will turn off to signal that the procedure has terminated
and the “enabling code” of the NEW transmitter has been trans
-
ferred).
Old New
B
A
7
In case of an error, LED (A) will indicate the type of error by ashing:
4 ashes: transfer of the “Enabling code” disabled
6 ashes: transfer of the “Enabling code” disabled between various
transmitters
10 ashes: communication error between the devices
15 ashes: memorisation failed due to expiry time exceeded.
l
After passing the enabling code on the NEW trans-
mitter, for the procedure to succeed the transmitter
within the rst 20 transmissions must be used at
least once near the automation.
ENCODING SWITCH PROCEDURE
4
4 ENCODING SWITCH PROCEDURE
MYGO (MYGO/A) transmitters operate by default with the one-way
“O-Code” (“O-Code/A”) radio encoding system. To satisfy back
-
ward-compatibility requirements, MYGO (MYGO/A) transmitters can
operate with the ET Blue, Piccinin and Linear encoding systems. To
make them transmit with a different type of encoding system, asso
-
ciated with a single button, the procedure described below must be
carried out.
To perform this procedure:
1. use an original transmitter that operates with the desired en
-
coding system
2. move the reference transmitter (A) near to the MYGO (MY
-
GO/A) (B) transmitter
B A
8
3. press and hold a button on the reference transmitter (A) until
LED (C) of the MYGO (MYGO/A) lights up
C
A
9
4. on the MYGO (MYGO/A) (B) press and release the button to
be associated with the new encoding system
5. LED (C) of the MYGO (MYGO/A) will signal the encoding
switch with a specic number of ashes:
1 = Opera encoding
2 = ET Blue encoding
3 = Peccinin encoding
4 = Linear encoding.
C
AB
10
In case of an error, LED (C) will indicate the type of error by ashing:
10 ashes = communication error between the devices
15 ashes =: memorisation failed due to expiry time exceeded.