Installation Instructions
13 – English
A.9 - Adjusting the acceleration (at the start of the awning movement) and deceleration
(towards the end of the movement)
NOTES AND WARNINGS
• “Acceleration/deceleration” is expressed in roller rotations. This is the number of rotations of the roller the system requires to accelerate from the start of the move-
ment to the cruise speed. It also represents the number of rotations of the roller the system requires to decelerate from cruise speed to stopping at the limit switch.
• The “nominal acceleration/deceleration” setting is the factory setting.
1 2 3
4
PRG
(x 1)
2
PRG
(x 1)
2
= 5 sec
3
Press and release
the button (1 time);
count 2 movements. Press and release
the button (1 time);
count 2 movements. Hold down the but-
ton and
release it after 5
seconds;
count 3 movements.
4 5
continues
= 5 sec
3
Select the
desired
option and
program it
as follows
(x ...)
5 OPTIONS:
1 press = sets no acceleration/deceleration = 0 rotations
2 presses = sets brief acceleration/deceleration = 0.7 rotations
3 presses = sets nominal acceleration/deceleration = 1.5 rota-
tions
4 presses = sets long acceleration/deceleration = 2 rotations
5 presses = sets maximum acceleration/deceleration = 3 rota-
tions
Hold down the
button and
release it after 5
seconds;
count 3 movements. Press and release the button the number of times indicated in the option you have
chosen;
5
6
end
7
sec.
?
1 /
2 /
3 /
4 /
5 /
= 5 sec
3
After about 7 seconds, the motor performs a num-
ber of movements equal to the number of pulses
entered.
Hold down the button and release it after 5 seconds; count 3 movements.
A
A.10 - Adjusting the total duration of the movement
NOTES AND WARNINGS
• This adjustment can only be done if the limit switches (“0” and “1”) have already been programmed.
• The value set with this procedure, together with the “acceleration/deceleration” setting (procedure A.9) determines the cruise speed. To determine whether the re-
sulting cruise speed is compatible with the awning (weight, roller dimensions, torque), refer to “Technical characteristics”.
• The factory setting is disabled.
1 2 3
4
PRG
(x 1)
2
PRG
(x 1)
2
= 5 sec
3
Press and release
the button (1 time);
count 2 movements. Press and release
the button (1 time);
count 2 movements. Hold down the but-
ton and
release it after 5
seconds;
count 3 movements.
A
4
5
end
7
sec.
?
1 /
2 /
3 /
= 5 sec
3
After about 7 seconds, the motor performs a num-
ber of movements equal to the number of pulses
entered.
Hold down the button and release it after 5 seconds; count 3 movements.