Installation Instructions

13 – English
A.9 - Adjusting the acceleration (at the start of the awning movement) and deceleration
(towards the end of the movement)
NOTES AND WARNINGS
“Acceleration/deceleration” is expressed in roller rotations. This is the number of rotations of the roller the system requires to accelerate from the start of the move-
ment to the cruise speed. It also represents the number of rotations of the roller the system requires to decelerate from cruise speed to stopping at the limit switch.
The “nominal acceleration/deceleration” setting is the factory setting.
1 2 3
4
PRG
(x 1)
2
PRG
(x 1)
2
= 5 sec
3
Press and release
the button (1 time);
count 2 movements. Press and release
the button (1 time);
count 2 movements. Hold down the but-
ton and
release it after 5
seconds;
count 3 movements.
4 5
continues
= 5 sec
3
Select the
desired
option and
program it
as follows
(x ...)
5 OPTIONS:
1 press = sets no acceleration/deceleration = 0 rotations
2 presses = sets brief acceleration/deceleration = 0.7 rotations
3 presses = sets nominal acceleration/deceleration = 1.5 rota-
tions
4 presses = sets long acceleration/deceleration = 2 rotations
5 presses = sets maximum acceleration/deceleration = 3 rota-
tions
Hold down the
button and
release it after 5
seconds;
count 3 movements. Press and release the button the number of times indicated in the option you have
chosen;
5
6
end
7
sec.
?
1 /
2 /
3 /
4 /
5 /
= 5 sec
3
After about 7 seconds, the motor performs a num-
ber of movements equal to the number of pulses
entered.
Hold down the button and release it after 5 seconds; count 3 movements.
A
A.10 - Adjusting the total duration of the movement
NOTES AND WARNINGS
• This adjustment can only be done if the limit switches (“0” and “1”) have already been programmed.
The value set with this procedure, together with the “acceleration/deceleration” setting (procedure A.9) determines the cruise speed. To determine whether the re-
sulting cruise speed is compatible with the awning (weight, roller dimensions, torque), refer to “Technical characteristics”.
• The factory setting is disabled.
1 2 3
4
PRG
(x 1)
2
PRG
(x 1)
2
= 5 sec
3
Press and release
the button (1 time);
count 2 movements. Press and release
the button (1 time);
count 2 movements. Hold down the but-
ton and
release it after 5
seconds;
count 3 movements.
A
4
5
end
7
sec.
?
1 /
2 /
3 /
= 5 sec
3
After about 7 seconds, the motor performs a num-
ber of movements equal to the number of pulses
entered.
Hold down the button and release it after 5 seconds; count 3 movements.