Buying Guide

45
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455
www.nibco.com
Visit www.nibco.com for current Chem-Guide and galvanic potential in piping systems information.
www.nibco.com
AHEAD OF THE FLOW
®
Revised 7/20/2018
MATERIAL LIST
PART SPECIFICATION
1 Valve Body Ductile Iron ASTM A536 65-45-12
2 Resilient Wedge Ductile Iron ASTM A536/EPDM ASTM D2000
3 Wedge Nut ASTM B584 UNS C83600
4 Dowel Pin ASTM A276 SS304
5 Stem Back Seat O-Ring EPDM ASTM D2000
6 Bonnet Gasket EPDM ASTM D2000
7 Bonnet Ductile Iron ASTM A536
8 Stem Packing EPDM ASTM D2000
9 Threaded Rod ASTM A276 SS304
10 Gland Bushing ASTM B584 UNS C83600
11 Gland Ductile Iron ASTM A536
12 Gland Nut ASTM B148 C95200 Aluminum Bronze
13 Yoke Ductile Iron ASTM A536
14 Yoke Bushing ASTM B150 C61400
15 Flat Point Set Screw ASTM F912M
16 Yoke Bushing Retainer Cast Iron ASTM A126 Class B
17 Handwheel Ductile Iron ASTM A536
18 Handwheel Nut Carbon Steel Zinc Plated
19 Stem Stainless Steel 304
20 Bonnet Screw Corrosion-resistant Steel
21 NPT Pipe Plug Steel ASME B16.14
22 UL/FM Label (not shown) Aluminum
23 Yoke Nut ASTM B148 C95200 Aluminum Bronze
24 Drive Screw Label (not shown) Stainless Steel 304
300 PSI CWP Iron Body Gate Valves
Fire Protection Valve • Outside Screw and Yoke • Resilient Wedge •
Epoxy Coated Interior/Exterior • Pre-Grooved Stem for Supervisory Switch •
Drilled, Tapped and Plugged at Boss Location A**
300 PSI/20.6 bar non-shock cold working pressure to 33°F to 160°F
Maximum working temperature 180°F at 250 PSI
F-607-RWS
Flanged
Position A
F-607-RWS
Flg x Flg
UL/ULC LISTED
• FM APPROVED • CERTIFIED LEAD-FREE*
BY TRUESDAIL LABORATORIES TO NSF/ANSI 61 & 372
Coating — Electrostatically applied fusion-bonded epoxy 8-20 mil. inside and outside
meets or exceeds AWWA C550. Epoxy coating is not intended to serve as a
dielectric barrier internal to the piping system.
** Drilled, tapped and plugged at Position A with ¹⁄₂" valve sizes 2¹⁄₂"–4", ³⁄₄" on 6"–8", 1" on 10"–12".
Compliance with the Standard for Gate Valves for Fire Protection Service, UL 262, and the
Canadian Requirements, ULC/ORD-C262.
NOTE: Flanged valve is consistent with ANSI B16.1 Class 125.
DIMENSIONS—WEIGHTS—QUANTITIES
Dimensions
Bolt
Size A B Open B Closed C D E F G Circle Flange Turns Weight
In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. Holes To Open Lbs. Kg.
2¹⁄₂ 65 7.5 190 17.8 453 14.9 378 0.69 17.5 7.0 178 7.9 200 1.50 38 1.42 36 5.50 140 4 6.3 39 18
3 80 8.0 203 19.7 500 15.9 405 0.75 19.0 7.5 191 7.9 200 1.73 44 1.42 36 6.00 152 4 10.0 44 20
4 100 9.0 229 21.0 534 16.6 422 0.94 24.0 9.0 229 10.2 260 2.13 54 1.42 36 7.50 191 8 10.0 72 33
6 150 10.5 267 29.3 744 22.9 581 1.00 25.4 11.0 279 12.4 315 2.24 57 1.54 39 9.50 241 8 15.0 117 53
8 200 11.5 292 37.0 939 28.5 724 1.13 28.6 13.5 343 14.8 375 2.48 63 1.54 39 11.75 298 8 16.7 198 90
10 250 13.0 330 44.8 1139 34.5 877 1.19 30.2 16.0 406 16.4 416 3.15 80 1.82 46 14.25 362 12 20.8 374 170
12 300 14.0 356 52.2 1326 39.9 1014 1.25 31.8 19.0 483 17.5 445 2.91 74 1.82 46 17.00 432 12 25.0 493 224
14* 350 15.0 375 62.2 1580 50.0 1270 1.38 35.0 21.0 533 19.7 500 2.95 75 3.20 81 18.75 476 12 43.8 620 284
16* 400 16.0 400 65.9 1674 50.4 1280 1.44 37.0 23.5 597 19.7 500 3.03 77 3.20 81 21.25 540 16 50.0 816 370
*14 and 16" valves 250 PSI CWP
FREEZING WEATHER PRECAUTION: Subsequent to testing a piping system,
valves should be left in an open position to allow complete drainage.
*Weighted average lead content ≤ 0.25%
WARNING: This product can expose you to chemicals including
lead, which is known to the State of California to cause cancer
and birth defects or other reproductive harm. For more information
go to www.P65Warnings.ca.gov.