Buying Guide
101
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455
www.nibco.com
Visit our website for the most current information.
www.nibco.com
AHEAD OF THE FLOW
®
Revised 7/20/2018
Iron Valve Options and Accessories
Tapping, Boss Locations, By-Passes*
Boss Locations
All NIBCO
®
iron valves are available with tapping for drain and special tapping. Boss locations and symbols
and tapping procedures are in accordance with MSS By-Pass and Drain Connection Standard SP-45. All
tappings are plugged at no extra charge. When Bosses are ordered tapped, the standard size of tapping
is in accordance with the following table taken from MSS Specification SP-45, table 1.
By-Passes
*
A By-Pass can be used to equalize pressure at inlet and outlet before opening main valve; facilitates
easy valve operation. Can also be used for preheating outlet lines and eliminate damage from too fast
expansion. The built up type By-Pass is available on all NIBCO iron valves and is attached in accordance
with MSS By-Pass and Drain Connection Standard SP-45. The By-Pass valve used on standard iron valves
is a globe valve. Specify by adding (Z) to Fig. No, i.e. F-000-Z.
Size of valve (In.) 2 2¹⁄₂ 3 4 5 6 8 10 12 14 16 18 20 24
Size of Drain Tapping (In.)
Series A (steam) ¹⁄₂ ¹⁄₂ ¹⁄₂ ¹⁄₂ ³⁄₄ ³⁄₄ ³⁄₄ 1 1 1 1 1 1 1
Main Valve Size (In.) 4 5 6 8 10 12 14 16 18 20 24
By-Pass Valve Size (In.) ¹⁄₂ ³⁄₄ ³⁄₄ ³⁄₄ 1 1 1 1 1 1 1
Sizes of By-Pass valves on NIBCO
®
Iron Gate, Globe, Angle and regular Swing Check Valves conform to
MSS Specification SP-45, Table II, Series A for steam service.
NIBCO INC. reserves the right to change materials, options and accessories without notice.
*By-Pass not available on F607-OTS