Operation Manual

61
The following controls are available:
PID Display: selects Hexadecimal or Decimal display for the PID values. Hexadecimal
PID displays are prefixed with “0x”.
Reset PID Statistics: if this button is clicked, the CC Error counts are reset to zero. Also,
the list of detected PIDs is also reset, and PIDs are re-discovered from the stream.
The PID monitoring results are displayed in a table with the following columns:
PID: discovered PID value. Only PIDs present in the stream are displayed. If a PID is
initially present and then disappears, it will remain in the able until the Reset PID
Statistics button is clicked.
Bit Rate: current PID bit rate, in bits/second. Bit rates are averaged every 2 seconds.
CC Errors: number of Continuity Counter errors detected in this PID.
PID Alarms Configuration Tab
The PID Alarms function is only available if PID Monitoring is enabled. If PID Monitoring is
disabled, the PID Alarms sub-tab will only contain this message:
Go to the PID Monitor Configuration Tab and enable PID Monitoring to configure the alarms.
Once PID monitoring is enabled, the alarms are available: