DSP version: This indicates the firmware revision for the decoding subsystem. The
format is Major Version Minor Version. DSP firmware will only occasionally be
updated by Niagara Video.
Serial Number: This is the serial number of this particular BRD card or stand-alone unit.
Hardware Version: This indicates the board version number. All board versions are
functionally equivalent.
Rear Module: This indicates the status of the Rear I/O Module. It can have one of the
following states:
o OK: The Rear Module is the correct module for the GOSTREAM BRD. In the
GOSTREAM BRDc/d this indicator will always indicate OK.
o Not Installed: The GOSTREAM BRD is not connected to a rear module. The
card is operating normally, but it will not be useful as there are no input and
output connections to it.
o Wrong Module: The GOSTREAM BRD is connected to a rear module that
was not designed for it (most likely from another openGear™ vendor).
Depending on the signals present on that module, there may be a small chance of
damage to the GOSTREAM BRD; Niagara Video recommends that this situation
be rectified immediately. This alarm will cause the front status LED to turn red.
Analog Audio Output: The BRD can be fitted with either balanced or unbalanced
analog audio outputs. The openGear GOSTREAM BRD can be ordered with either
balanced or unbalanced rear I/O panels. The same card will support both types. The
stand-alone GOSTREAM BRDc/d factory-configured with balanced or unbalanced audio
at the time of ordering. This parameter indicates the type of analog audio installed with
this decoder.
Card Uptime: Indicates how long the card has been running since it was last rebooted.
Ambient Temperature: Temperature, in degrees centigrade, of the air intake of the card
(measured at the front edge of the card).
Internal Temperature: Temperature, in degrees centigrade, at the back of the card.
MDP Core Temperature: Temperature, in degrees centigrade, of the core processing
element.
Card Power (W): Indicates the current power draw of the unit, in watts.
The openGear™ frame is designed to operate in environments with up to 40
o
C ambient. There is
typically a 5
o
C temperature raise from the external ambient to the “Ambient Temperature”
measured by the GOSTREAM BRD. If that measurement is at 45
o
C or higher, action must be
taken to cool down the ambient temperature. The GOSTREAM BRD will log excessive
temperature events.
The GOSTREAM BRD stand-alone version is designed to operate in environments with an
ambient temperature between 0 and 50
o
C.