User's Manual

DEVICE SETTING TIPS
Please note this device supports operation using both batteries (AA battery x4) and power from existing
doorbell power lines (9V~36V AC/DC); however, there are certain function limitation when the device is
running under battery mode:
*Once the device is in sleep mode; the user can no longer access the device from their mobile
device. The device will only become online when the motion detector has detected an event,
or by pressing the power button at the bottom of the device.
Device will return to sleep mode after:
After device wakeup on visitor call or motion-detect event; the device will automatically goto sleep
mode again in any of the following conditions:
A. When preset power saving time (30s/60s/90/120s) is reached after a visitor or motion events
B. After user answer a visitor call or check live view from a motion-detect event using the APP and
then exit the APP.
C. When device cannot connect to the pre-set Wi-Fi network for any reason; the device will retry the
connection for 30 seconds, if Wi- connection still can not establish after 30 seconds, the reconnect
attempt will be stopped and the device will enter power saving mode again.
How to Maximized Battery Power:
When device is using battery power, we suggest using the following setting to maximize battery power
• Install the doorphone where it can receive excellent Wi-Fi network signals (Weak Wi-Fi signal will force
doorphone to operate using higher Wi-Fi Power, which may consume more power).
• Set Auto Sleep Timer to 30 seconds.
• Do not stay in live view or system setting mode unless it’s necessary.
(1) While in the device list section, tap to bring up edit option icons.
(2) Tap to enter System Info
(3) Select "Advanced" and enter default password: 123456.
(4) Scroll down to the Power Saving section and select desire power saving time.
Note:
It is suggested to set the Power Saving to 30 seconds to maximize battery power.
POWER SAVING MODE
Note: For remote door unlock function with 12V/1A current output trigger, the direct input
power must be higher or equal to AC or DC 15V/1.5A.
ADDITIONAL WIRING DIAGRAMS
A. Electronic Lock
++
Lock
- -
C. Electronic Gate(2/4-Wire Type Connection)
Gate
4-WIRE TYPE CONNECTION DIAGRAM
2-WIRE TYPE CONNECTION DIAGRAM
Power
Input
Power
B2
B1
B2
B1
B. Existing Bell Wiring
- -
++
DoorBell
Live View
Live View