NEXTTEQ LLC 8406 Benjamin Road, Suite J Tampa, FL 33634 USA http://www.nextteq.com / email: info@nextteq.com TEL: 813-249-5888 / Toll free: 877-312-2333 FAX: 813-249-0188 / Toll free: 877-312-2444 © 2005 Nextteq LLC All Rights Reserved. Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form and by any means, electronic or mechanical, for any purpose without the express written permission of Nextteq LLC.
M8 Detection Paper Manual Table of Contents Contents I. INTRODUCTION..................................................... 1 II. SPECIFICATIONS.................................................... 2 III. WARNINGS . ........................................................ 3 IV. MSDS................................................................. 8 V. OPERATING INSTRUCTIONS .....................................14 Nextteq LLC 8406 Benjamin Road, Suite J, Tampa, FL 33634 www.nextteq.
Introduction M8 Detection Paper Manual I.
M8 Detection Paper Manual Specifications II. SPECIFICATIONS Weight: Dimensions: Sampling Temperature: Minimum Detectable Concentration: Color Unreacted: Color Changes: Storage Temperature: Storage Condition: Shelf Life: 0.6 oz (17 g) 4 in L x 2.5 in W x 0.375 in D (10 cm L x 6.5 cm x 0.95 cm) -26°F to 120°F (-32°C to 49°C) 0.
Warnings M8 Detection Paper Manual III. WARNINGS 1. Before using this product, read, understand, and comply with all labels, warnings, instructions, and other literature accompanying the product, including but not limited to, this manual and the MSDS in this manual (also available as P/N 90013 Rev B 3/06). Failure to comply with all warnings and instructions could cause serious injury. 2. Only use the product in strict compliance with the manufacturer’s specifications and instructions.
Warnings M8 Detection Paper Manual 10. Do not rub paper on skin. If paper comes in contact with skin, immediately wash exposed area with soap and water. 11. Do not place paper in eyes. If paper comes in contact with eyes, flush immediately with clean water, including under eyelids for at least 15 minutes. 12. Do not eat, drink, take internally, or consume paper. Consuming paper may result in serious injury, sickness, or death. 13. Do not heat or expose paper to open flame.
M8 Detection Paper Manual Warnings 20. Do not distribute M8 Detection Paper without a complete set of Nextteq instructions, warnings, and specifications. Distributing M8 Detection Paper without a complete set of warnings, instructions, and specifications may result in misuse and lead to serious injury or death. 21. This product(s) is designed for use in ambient atmospheres of -26°F to 120°F (-32°C to 49°C). 22. Do not store in direct sunlight.
M8 Detection Paper Manual Warnings INSTRUCTIONS, WARNINGS, LABELS, AND MANUALS BEFORE USING AND WHILE USING NEXTTEQ’S PRODUCTS. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS CONTAINED IN THIS DOCUMENT ARE BASED UPON DATA AND OTHER INFORMATION THAT NEXTTEQ BELIEVES TO BE CORRECT AND COMPLETE AS OF THE DATE ISSUED, BUT THE ACCURACY AND COMPLETENESS THEREOF IS NOT GUARANTEED AND NO WARRANTY OF ANY KIND IS MADE WITH RESPECT TO THE INFORMATION OR RECOMMENDATIONS CONTAINED IN THIS DOCUMENT.
Warnings M8 Detection Paper Manual THE PROPER USE OF M8 DETECTION PAPER, ANY INSTRUCTIONS, WARNINGS, LABELS, SPECIFICATIONS, TEST PROTOCOL, OR THE M8 DETECTION PAPER MANUAL, THE USER SHOULD CALL NEXTTEQ FOR ASSISTANCE PRIOR TO USING THE PRODUCT. NEXTTEQ CAN BE CONTACTED AT ONE OF THE FOLLOWING TELEPHONE NUMBERS: TOLL FREE 877-312-2333 OR LOCAL NUMBER 813-249-5888.
M8 Detection Paper Manual MSDS IV. MSDS MSDS for M8 Detection Paper P/N 90013 Rev. B 3/06 Section 1 – Material Identification Product Name: M8 Detection Paper Section 2 – Composition/Information on Ingredients Substance Name: M8 Detection Paper Ingredient Names: 1) Dye Red E 2) Dye Green EDA 3) Dye Yellow A2 4) Rosin 5) Alum 6) Paper pulp 0.4-0.8% 0.7-1.3% 0.8-1.
MSDS M8 Detection Paper Manual Dye Green Not established by ACGIH Dye Yellow A2 Not established by ACGIH Rosin Not established by ACGIH Alum. ACGIH-TLV: TWA 2 mg/m3 Paper pulp Not established by ACGIH Section 4 – First Aid Measures ORAL EXPOSURE: If swallowed, wash mouth out with water (provided person is conscious). Call a physician. DERMAL EXPOSURE: In case of contact, immediately wash skin with soap and water. If irritation occurs or persists, seek medical attention.
M8 Detection Paper Manual MSDS Section 6 – Accidental Release Measures N/A Section 7 – Handling and Storage HANDLING: User Exposure: Avoid contact and inhalation. Do not get in eyes, on skin, or on clothing. STORAGE: Suitable: Store in a cool dry place. Store away from incompatible materials and potential sources of ignition. Section 8 – Exposure Controls / PPE ENGINEERING CONTROLS: Do not use in unventilated spaces.
MSDS M8 Detection Paper Manual Section 11 – Toxicological Information ROUTE OF EXPOSURE Eye: Because this is a solid material and not a powder or dust, it is not expected to be a route of exposure. If paper comes into contact with eyes, flush immediately with clean water, including under eyelids for not less than 15 minutes. Skin: Repeated or prolonged skin contact may cause dermatitis. In case of contact with skin, immediately wash exposed area with soap and water.
M8 Detection Paper Manual MSDS Section 16 – Special Precautions & Comments Class of Users: This product is only to be sold to, only for use by, and only for storage by trained, qualified, professional industrial or commercial users. Handling & Storage: Store in the original container in a cool dry place. Protect against light, heat, moisture, and physical damage.
MSDS M8 Detection Paper Manual THIS PRODUCT OR COMPONENT IS ONLY FOR SALE TO, FOR USE BY, AND FOR STORAGE BY A TRAINED, QUALIFIED, PROFESSIONAL, COMMERCIAL, OR INDUSTRIAL USER. THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION SET FORTH IN NEXTTEQ’S TERMS AND CONDITIONS OF SALE.
M8 Detection Paper Manual Operating Instructions V. OPERATING INSTRUCTIONS A. Recommended Usage Nextteq recommends the following in regards to use of M8 Detection Paper: A. M8 Detection Paper does not detect gases or vapors. M8 Detec- tion Paper detects liquid chemical warfare agents. B. Do not attach M8 Detection Paper to hot, oily, or greasy surfaces. Hot, oily, or greasy surfaces may cause a false positive. C.
Operating Instructions M8 Detection Paper Manual C. Eye protection in accordance with OSHA standards and good practice. Contact lenses should be worn in strict compliance with applicable NIOSH, OSHA, and ACOEM standards. D. Chemical resistant clothing in accordance with OSHA stan- dards and good practice. 6. This product(s) is designed for use in ambient atmospheres of -26°F to 120°F (-32°C to 49°C). 7.
M8 Detection Paper Manual NOTE: D. Operating Instructions The following substances or conditions may cause false positive or false negative readings in M8 Detection Paper: • Ammonia • Petroleum Products • Organic Solvents (such as pesticides) • Hot greasy oily surfaces • “Break Free” (a brand of weapon cleaner and lubricant) • Decontamination solution 2 (DS2) • Storage and Disposal 1. Store M8 Detection Paper in original sealed bag in a cool, dry place away from light, heat, moisture, and damage. 2.