Installation Guide
19
CORNER INSTALLATION
All products must be allowed to acclimate; removed fr om boxes and stored flat at the
installation site for a minimum of 48 hours or until properly acclimated prior to installation.
Heat and moisture cause expansion. Best results are obtained by installing a cool, dry
product. NextStone™ does not warrant against gapping caused by expansion and contraction
or improper installation.
Step 1
Metal Starter Strip - Determine at what height above grade level
you want the panel to sit on. Measure up 2 ¾" from this point and
strike a level line. Attach the top of the starter strip on this line.
End the strip 2" from each side of the corner.
Step 2-Set the Stacked Stone outside corner piece against the
corner and down into the starter strip. Use the screw guides
and place at least 3 screws along the tongue. Place 2 screws
in the right lap side of the panel where indicated. (Fig. 7).
Figure 7
Step 3-Attach the panels working out from each side
of the corner as previously described. (Fig. 8)
Figure 8
Note: There ar e 4 patter ns of the Stacked Stone Outside
Corner. 2 Left patterns and 2 right patterns. Check for
numbers on the backside of each corner piece. They are
numbered 1 through 4. Alternate left and right corners with
each course to ensure offsets and to prevent pattern
repetition.
STACKED STONE OUTSIDE CORNER