User's Manual
NETWORKED SMART BOOSTER 11
Specifications
QRE – ALL LEDs
FLASHING
Any RJ45 green
LED is off
between
NU/QRE/CU
Supported Bands 2, 4, 5, 12
WCDMA Bandwidth per Band 3.84, 5, 10, 15, 20 MHz contiguous UMTS/HSPA channels
LTE Bandwidth per Band 5, 10, 15, 20 MHz contiguous (up to band max)
Channel Selection Full Auto with self-learn Scan
Downlink TX Power max (conducted) 10dBm/5MHz (16dBm per band per antenna, 19dBm per band)
Uplink TX power max (conducted) 22dBm per band per antenna, 25dBm total per band
Max boost bandwidth (all channel) 75MHz
Maximum System Gain 100dB
System Gain dynamic range 0-100dB (real time echo controlled)
Internal MIMO antenna gains 0-2dBi (band dependent) V-H polarization
External RF connections 50 ohm QMA female Quick-Connect
Ethernet ports Shielded Fast Ethernet ports (RJ45)
Maximum NU-CU cable length 100 meter (200 meter with QUATRA Range Extender accessory)
NU-CU LAN cabling Cat 5e or better
Bluetooth (NU and CU) Bluetooth Low Energy (BLE) v4.1.2
User Interface Red/Green LEDs, QMT Smartphone App, WAVE Cloud Portal
Input Power (NU only) 54 VDC @ 2.22 Amp via external supply (51.3 to 56.7 VDC tolerance).
External Power Supply (NU only) 100 to 240 VAC, 47 – 63Hz.
Cooling Natural convection
Network Unit dimensions 264mm (W) x 185mm (H) x 62mm (D)
Coverage Unit dimensions 225mm (W) x 185mm (H) x 36.5mm (D)
Network Unit weight 1.2 kg (40.8 oz.)
Coverage Unit weight 0.83 kg (29.2 oz.)
Operating temperature 0° to 40°C
Storage temperature -25° to 60°C
Relative humidity 0% to 95%, noncondensing
IP Rating IP20
Compliance RoHS II 2011/65/EU
3GPP TS 25.143 Rel.10
3GPP TS 36.143 Rel.10
FCC Part 15, 20, 22, 24, 27
UL STD 62368-1
CSA STD C22.2 No. 62368-1
Bluetooth BQB
Troubleshooting: Accessories
LED ISSUE TRY
Link is down
Unplug the INPUT cable, wait 5 seconds, and plug it back in. If the condition persists the unit needs to be replaced.
CU is not connected or cannot be seen. Check QRE to CU cable and/or CU. CU may be checked by plugging directly
to back of NU or QRE Output with LAN test cable. Check NU – QRE – CU cables lengths (must not exceed 100
meters each, and use of patch panels may reduce maximum length).
LED ISSUE TRY
OUTPUT