User's Guide
9/10/2019
13
Waterproof RJ45 Inline connectors assembly
This section applies to all the components in the Cel-Fi QUATRA RED solution using RJ45 connectors. Use
a CAT 5e cable or higher category to interconnect the units. Each QUATRA RED component includes a set
of waterproof RJ45 inline connectors to be installed on each side of the Ethernet cable.
1. Pass the cable thru the screw-on cap
2. Insert the cable into the split sleeve and washers
3. Push the screw-on cap and washers in the receptacle
4. Apply on the screw-on cap a maximum mating torque of 4.1 - 6.1 in-lbs
Figure 2. Waterproof RJ45 Inline connector assembly
Installing the Monitor and Battery Backup Unit (MBBU)
The Monitor and Battery Backup Unit (MBBU) is the centerpiece of the QUATRA RED system. The MBBU
processes all alarming, DC power, service configuration, and system control. The installation procedure
described in this manual is identical for both models F42-10S-100 and F42-10L-100.
Note: Even though this manual explains how to install and wire the batteries inside the MBBU, the unit
doesn't include the batteries. Please contact your distributor to select and purchase the batteries that
support the requirements in your area.
MBBU Unpacking and Package Content
When receiving the MBBU, perform the following checks:
Inspect the shipping container for damage before unpacking the unit.
Look for any physical damage to the equipment.
Check that all the items listed in the packing list are included.
MBBU Wall Mounting
The Cel-Fi QUATRA MBBU is designed to be wall-mounted. Mounting accessories, including screws and
anchors, for common material types (drywall, plywood, etc) are included in the standard kit.
The QUATRA RED MBBU has nine (9) secure mounting tabs, six on the top and three on the bottom side.