Instructions / Assembly

Water-Saving Tips
The following steps illustrate adjustments to the Mini-Valve
®
and Quick Flush Float to maximize savings.
IMPORTANT NOTE
Adjustment is for Quick Flush. Rippling will occur on Full Flush.
Adjust Blue Float. Top of Float must be at least 1/2˝ (13 mm)
below water level.
In most cases water level can be raised by adjusting the fill valve.
Quick Flush = Blue Float
Up = less water Down = more water
Full Flush = Green Slide
Up = less water Down = more water
21
A Thumb Screw is provided to fine-tune adjustments to float. Proper
water level should be indicated inside tank or 1/2˝ to 1˝ (13 - 25 mm)
below overflow tube.
19
20
NOTE: Refill Tube must be positioned above overflow tube.
DO NOT INSERT REFILL TUBING DOWN OVERFLOW PIPE.
This improper installation violates plumbing code and couldresult in a leak.
DO NOT OVERTIGHTEN. We recommend replacing an old, rigid metal
water supply. We recommend replacing an old, rigid metal water supply
line with a flexible, braided supply line.
DO NOT USE PLUMBER'S PUTTY TO SEAL FITTINGS.
17
18
Cone
Washer
Turn on water and when water is clear, disengage Float Lock to fill tank.
This willprevent debris from plugging up Valve.
Thumb
Screw
METAL/COPPER
FLARED TUBING
METAL
FLANGED TUBING
VINYL/BRAIDED
CONNECTOR
RECOMMENDED
WARNING
Float Lock
Blue Float
Green Slide
Begin with the
Mini-Valve in the
OPEN position
Flush the Quick Flush
button/handle and watch
as the bowl refills.
If the water is lower
than the pencil mark
after the tank fills…
… adjust the Quick
Flush Blue Float
downwards, or open
Mini-Valve.
If the water
continues to
ripple after
reaching the
pencil mark…
…turn
the Mini-Valve
counter-clockwise.
Open
Continue adjusting the
Mini-Valve or Blue Foat
until the water reaches the
pencil mark at the same time
as the tank finishes filling.
Your Fill Valve and
Dual Flush Converter
are now calibrated to
save you thousands of
gallons (litres) of water
year after year.