Product Manual
6
points.
Be sure the sensor is positioned vertically with the mounting bracket at the top. Verify the sensor is not tilted in any way.
IMPORTANT: If a vent hole is drilled in the discharge pipe make sure a sensor or sensor clamp does not block the vent hole.
Do not position the sensor on the side of the discharge pipe facing the drain tile or any incoming rush of water.
Step 2: Secure Wires
Secure the pump and sensor wires to discharge pipes with nylon wire ties.
IMPORTANT: Make sure the wire ties or wires do not interfere with the operation of the sensor.
Step 3: Position Battery and System Unit
Place the battery in a battery box (if used) on the floor or on a secure shelf, rack or ledge. Position the NexPump system unit in a
secure place ideally above the floor. The pump wires and sensor wires should be long enough to position the NexPump system
unit approximately 3-4 feet above the floor. Be sure the power cord will reach the AC power socket. Secure the electrical power
cord as needed. Do not plug in at this time. Make sure battery cables will reach battery. Do not connect battery cables at this
time.
Step 4: Pump and Sensor Connections
Plug the pump connectors into the NexPump system unit. If both pumps are not on the bottom of the pit then Pump 1 must be the
lowest pump. Plug in the sensors. Primary sensor (Sensor 1) to left receptacle. Backup sensor (Sensor 2) to right receptacle. The
sensor connectors plug in with the security latch to the right of the NexPump System Unit. Verify the sensor connectors are
securely attached.
IMPORTANT: Ai Turbo NexPump. Pump 1 must be the pump with the RED WIRE LOOM.
To disconnect a pump connector, slightly depress the security latch on the bottom of the connector and pull out the connector.
To disconnect a sensor connector, slightly depress the security latch on the right side of the connector and pull out the connector.
Step 5: Connecting the AC Power Cord
IMPORTANT: Make sure that the AC outlet is a grounded outlet.
Plug in the NexPump's AC power cord and verify a secure connection. The display will illuminate and ‘Operating Status’ Green
LED should be blinking.
Note: An alarm may sound at this time because the battery is not connected.
Step 6: Connect Battery
Attach the battery cables to the battery, the BLACK wire to the NEGATIVE (-) post, the RED wire to the POSITIVE (+) post and
tighten securely.
IMPORTANT: Check the ‘Battery Reverse’ LED on the NexPump system unit and if it is illuminated the connections are
reversed.
Step 7: Check Your NexPump
All alarms should be off at this time. Set your preferred mode setting (see mode selection). The NexPump will schedule an
automatic self-test approximately two minutes after power up. If there are any alerts they will be displayed on the LCD display
and an alarm will sound.
Step 8: Secure Battery Boxes
If battery boxes are used, place each battery in the battery box.
Step 9: Set Battery Type/Amp Hours and Enable Charger
These all can be found in the configuration menu. Use the up and down arrows on the navigation panel to find the configuration
menu then press ENTER. Use the left and right arrows to move the cursor/increase the amp hours and the press ENTER when
cursor is on desired position.
Note: Always perform this step when installing new batteries.
Your NexPump is ready for use!