Alerts
The NexPump system monitors 38 critical points on the unit. In the case of an alert the system will alarm followed by a
notification if you have that option.
Normal Alerts
Pump Activation
AC Power Loss
Notifications: After approximately thirty minutes
Note: Pump Activation lets you know there may be an issue with your main pump. If you find you have a problem with your main
pump you can switch the NexPump mode to 'Primary' until the main pump problem is corrected.
Critical Alerts
All other alerts
After approximately five minutes, except a High Water Alert, which is approximately one minute.
Silencing or Un-Silencing the Alarm
The alarm can be silenced for normal alerts only. It will silence for
24 hours. A silenced alarm clears automatically after 24 hours.
To silence or unsilence alarm press Enter when on menu ‘Silence
Alarm (24H)’ or ‘unsilence alarm.’
Note: When the alarm is silenced the alerts will blink to notify which
conditions are in the alarm state.
Disabling or Enabling the Alarm
The alarm can be disabled if needed. When disabled, the alarm will
not sound for any reason. The alarm will stay disabled for five days
and automatically be enabled after that time. You can enable the
alarm before the five day period by selecting the Enable Alarm menu
and pressing ENTER.
Note: All notifications will take place while the alarm is disabled,
disabling the alarm simply turns off the sound.
Alert History
Under the information menu you can retrieve the history of the last
ten alerts registered. The date and time will be displayed with the
alert.
To find the alert history select the information menu and once on the
screen ‘Alert History Display’ use the left and right arrows to move
the cursor then press ENTER.
Displaying Alerts:
Below are two examples of what the display will look like when there are alerts on the NexPump. Line two of the display will
show you each alert approximately every three seconds. The first example will let you know the number of alerts and the current
number it will be displaying. The format will be 'Alert x of x'. The second example is the actual alert that follows the first
example.
Alert History
Display ? Y N
Silence Alarm? (24H)
Disable Alarm? (5D)