Product Manual

12
Battery Connected Improperly
If the battery cables are connected to the wrong posts, the ‘Reversed
Polarity’ red LED will illuminate and an alarm will sound for 'Battery
Problem.’
Note: Correct by reversing the battery cables.
Battery Type
Be sure to select the battery type installed with the system. This
screen can be found under the configuration menu.
Use the left, right arrows and press ENTER when cursor is over
desired position.
Battery Amp Hours
Select the battery amp hours on your battery. If multiple batteries are
connected add the total amp hours together. This can be found in the
configuration menu.
Use the right and left arrows to increase or decrease amp hours.
When on desired number press ENTER.
Battery Charger
The charger should be turned on when the system is first installed or
when replacing the batteries. This can be found in the configuration
menu.
Use the left, right arrows and press ENTER when cursor is over
desired position.
Battery Timer
Batteries have a lifespan and should be replaced when the NexPump
reports this time frame has expired. This should also be reset when
replacing batteries. Defaults for battery type selected. (WET = 1300
days, 3.5 years, AGM = 1600 Days, 4.5 Years)
This can be found in the Reset menu. To select use the left and right
arrows and press ENTER when cursor is over desired position.
Battery Information
This screen can be found under the information menu.
BA=current amp hours of your battery
Batt=battery type
Replace battery= how many days until the system recommends
changing the battery
Battery Type ? W A
W=Wet A=AGM,Gel
Charger ? On Off
Battery Amps ? 105AH
Reset Battery Timer?
Confirm ? Y N
BA=105 AH
E/S=On Batt=Wet
Replace Battery
In: 1350 Days