User Manual
6 
LED 
MODE 
INDICATES 
On 
Compressor Enabled 
Flashing 
Anti-Short Cycle Delay Enabled (AC Parameter) 
On 
Defrost in Progress 
Flashing 
Dripping in Progress 
On 
Fans Output Enabled 
Flashing 
Fans Delay After Defrost 
On 
Measurement Unit 
Flashing 
Programming Mode 
NOTE: Your new refrigerator is already factory-set to run at optimum temperatures for food safety and 
should require no adjustments. Your refrigerator is set to cycle between a minimum temperature of 
33°F and a maximum temperature of 40°F. Adjusting the temperature changes the minimum 
temperature your unit will run at. Your refrigerator will not run constantly at this temperature setting 
HOW TO VIEW THE SET TEMPERATURE 
1.  Push and immediately release the SET key, the set temperature will be displayed. 
2.  To return to standard view, wait about 5 seconds or push and immediately release the SET key 
again. 
HOW TO CHANGE THE SET TEMPERATURE 
1.  Push and hold the SET key for 2 seconds. 
2.  The °F LED will start to blink and the current temperature will be displayed. 
3.  To change the set temperature push the  or   arrows. 
4.  Push the SET key to store the new temperature or wait 10 seconds and new temperature will 
automatically be set. 
HOW TO START A MANUAL DEFROST 
NOTE: Units are pre-programmed to run automatic defrost cycles at preset intervals. If you would like to 
run a manual defrost cycle at any time, follow these instructions: 
1.  Push and hold the key for 2 seconds. 
2.  Repeat to stop the defrost cycle. 
Refrigerator coils are kept below the freezing point (32°F). During compressor down-time, the 
evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil 
temperature above the freezing point, melting any accumulated frost. Run-off water is drained into the 
evaporator pan and evaporated. 