User Manual

6
LED
MODE
INDICATES
On
Compressor Enabled
Flashing
Anti-Short Cycle Delay Enabled (AC Parameter)
On
Defrost in Progress
Flashing
Dripping in Progress
On
Fans Output Enabled
Flashing
Fans Delay After Defrost
On
Measurement Unit
Flashing
Programming Mode
NOTE: Your new freezer is already factory-set to run at optimum temperatures for food safety and
should require no adjustments. Your freezer is set to cycle between a minimum temperature of -5°F and
a maximum temperature of 2°F. Adjusting the temperature changes the minimum temperature your
unit will run at. Your freezer will not run constantly at this temperature setting.
HOW TO VIEW THE SET TEMPERATURE
1. Push and immediately release the SET key, the set temperature will be displayed.
2. To return to standard view, wait about 5 seconds or push and immediately release the SET key
again.
HOW TO CHANGE THE SET TEMPERATURE
1. Push and hold the SET key for 2 seconds.
2. The °F LED will start to blink and the current temperature will be displayed.
3. To change the set temperature push the or arrows.
4. Push the SET key to store the new temperature or wait 10 seconds and new temperature will
automatically be set.
HOW TO START A MANUAL DEFROST
NOTE: Your new freezer is pre-programmed to run automatic defrost cycles at preset intervals and for
pre-determined durations. To run a manual defrost cycle at any time, follow these instructions:
1. Push and hold the key for 2 seconds.
2. Repeat to stop the defrost cycle.
Freezer coils are defrosted electrically. Automatic defrost timers automatically initiate at pre-set
intervals and for a predetermined duration.