19
European Siding System-Horizontal Installation Guide / v20231116US
Click to return to Content Table
Diagram 5
Detail 5-1
Detail 5-3
Detail 5-4
5
Install the Starting Trim (AW02) at the
end of the joists opposite the floor with
screws, as shown in
Diagram 5
.
Detail 5-1
Starting Trim (AW02)
Note:

A minimum gap of 3/16" (5mm) needs
to be left between the Starting Trim
(AW02) and the F-Trim (UH50), as shown
in
Detail 5-1 and 5-2

A minimum gap of 7/16" (11mm) and 2
1/2" (63mm) needs to be left between
the Starting Trim (AW02) and the
adjacent wall in the inside corner, as
shown in
Detail 5-3

A minimum gap of 3/16" (5mm) needs
to be left between the Starting Trim
(AW02) and the Outside Corner Trim
(UH51), as shown in
Detail 5-4
Wall
Outside
Corner Trim
(UH51)
Min 3/16"
(5mm)
Furring
Strip
Starting
Trim
(AW02)
Wall
Starting
Trim
(AW02)
Furring
Strip
Min 7/16"
(11mm)
Min 2 1/2"
(63mm)
Min 3/16"
(5mm)
Wall
Furring Strip
Outside
Corner Trim
(UH51)
Starting
Trim
(AW02)
Detail 5-2
Wall
Starting
Trim
(AW02)
F-Trim
(US73)
Furring
Strip
min 3/16"
(5mm)