Installation Guide
11
European Siding System-Horizontal Installation Guide / v20231116US
Click to return to Content Table
Furring Strips Installation
A building professional should be consulted regarding vapor barriers and insulation for your project.
Where a vapor barrier is to be used, it should be a breathable type and must be positioned behind the
furring strips. The furring strip needs to have a minimum thickness of 1" (25mm).
Wood furring strips should be xed into position at a maximum of 16" (406mm) centers using a suitable
A4 Stainless Steel Countersunk Wood/Masonry screw. All furring strips needs to be flat and leveled
against the wall surface use shims if necessary.
Furring Strip
.UXO`UTZGR/TYZGRRGZOUT
16"
(406 mm)
16"
(406 mm)
Furring Strip
<KXZOIGR/TYZGRRGZOUT
16"
(406 mm)
16"
(406 mm)