Installation Guide
36" Hybrid Composite Railing Installation Guide / v20181120 6
DIAGRAM 1
DIAGRAM 2
DIAGRAM 3
1
Mark where the post mount (J-R0221-36)
will be installed. The maximum distance
of the post mount is 1923 mm (75.7") from
center to center as shown in diagram 1.
2
Cut post mount (J-R0221-36) to the length
of 937 mm (36.9") as shown in diagram 2.
Cut post sleeve (N-UH35) to the length of
991 mm (39") as shown in diagram 3.
DIAGRAM 4
DIAGRAM 5
3
Install the post mount (J-R0221-36) as
shown in diagram 4-15.
Note: Screw WJ0094 is used when installed
on concrete. Screw WJ0155 is used when
installed on wood.
Installing on a concrete surface
a. First position the post with the metal base in
the position of installation. Then use a marker
or pencil to mark the drilling hole positions as
shown in Diagram 4.
b. Now take a drill and drill in the spots marked
previously as shown in Diagram 5.