Users Manual
NTSecureGateway 10 / 14
User Manual
11648_0008_0012_UM-User_Manual
Revision: DV A1
NewTec GmbH · Buchenweg 3 · 89284 Pfaffenhofen a.d. Roth · Germany · Tel.: +49 7302 9611-0 · product-support@newtec.de · www.newtec.de
F905
Security Features
• Dedicated cryptographic hardware engine (ARM TrustZone)
• Cryptography and security middleware services·
• Secure Boot
• Secure Update
• Various supported encryption algorithms, such as AES, RSA, Diffie-Hellman, Elliptic Curve
• Tamper Protection
• ATECC608 Secure Keystore
Technical Data
Dimension
Figure 3: Dimension in mm
Maximum Ratings
Supply Voltage
7 VDC ... 32 VDC
Operating Current
Max: 0.5A @24V
Storage Temperature
-15 °C to +70 °C
Operating Temperature
0 °C to +40 °C
Protection class
IP20
Condensation
Not allowed
Table 1: Maximum Ratings