Safety data sheet
—Material Safety Data Sheet—
υ Datas and dimensions are just reference values.For further details,please
contact us through the phone or email above.
υ Contents are subject to change without notice.
Document Number: MSDS-SWT - CR / 05E1
Revisedl:
2006-12 Page 10 of 13
Newsun
@
Table2.
Items Conditions Requirements
Heat endurance
test
Cells are kept stored for 24hrs. at :
temperature
80±2 , humidity 70%RH and less.℃
Open-circuit voltage is to be
kept same as initial value . No
abnormal appearance and no
substandard dimensions are to
be abserved.
Vibration
endurance test
Entire amplitud : 1.0mm Frequency :
10~55~10Hz
Sweep : 1minute
Period : 2h×2(Direction X,Y)
Ditto
Falling
endurance test
Cells are fallen 10 times from the height
of 75cm onto solid wood with thickness
of 3cm without fixing falling angle.
Ditto
Weighing
endurance test
Weight of 2kg is laid for 1hour and 1kg
for 24hour respectively on all over
negative side of cells.
Ditto
Short-circuit test
Cells are Short-circuited for 48hours. No burst and firing will occur.
2、SGS Test
Test Method: (1)With reference to standard analytical method by European Battery
Association (EPBA).Battery Association of Japan(BAJ )and National Electrical Manufacturers
Association (NEMA ,USA )-April 1998.Samples were digested in concentrated nitric acid and
hydrogen peroxide.Analysis was performed by atomic absorption or inductively coupled argon
plasma spectrometry.(2)As specified in EPA method 3060A & 7196A .The smple was alkaline
digested by using EPA method 3060A ,and then analyzed ny using colorimetric method 7196A .
With reference to SGS in-house method . Analysis was performed by GC /MS
Test Result :
Table3.