Safety data sheet
Material Safety Data Sheet
Document number:
MSDS-SWT - CR / 05E1 Revised 2006-12
Section Ⅺ– Other Information
UL Test
Items Conditions Requirements
Heat endurance test Cells are kept stored for 24hrs. at :
temperature
80±2, humidity 70%RH and less.
Open-circuit voltage is to be
kept same as initial value . No
abnormal appearance and no
substandard dimensions are to
be abserved.
Vibration endurance
test
Entire amplitud : 1.0mm Frequency :
10~55~10Hz
Sweep : 1minute
Period : 2h×2(Direction X,Y)
Ditto
Falling endurance
test
Cells are fallen 10 times from the height of
75cm onto solid wood with thickness of 3cm
without fixing falling angle.
Ditto
Weighing endurance
test
Weight of 2kg is laid for 1hour and 1kg for
24hour respectively on all over negative side
of cells.
Ditto
Short circuit test Cells are Short-circuited for 48hours. No burst and firing will occur.
SGS Test
Test Method: (1)With reference to standard analytical method by European Battery Association
(EPBA).Battery Association of Japan(BAJ )and National Electrical Manufacturers Association (NEMA
,USA )-April 1998.Samples were digested in concentrated nitric acid and hydrogen peroxide.Analysis was
performed by atomic absorption or inductively coupled argon plasma spectrometry.(2)As specified in EPA
method 3060A & 7196A .The smple was alkaline digested by using EPA method 3060A ,and then
analyzed ny using colorimetric method 7196A . With reference to SGS in-house method . Analysis was
performed by GC /MS