Operation Manual
Condensation accumulates on the parts.
It is O.K. to use the scope in cold. However, when the unit is brought
from the cold into a warm environment, it has to warm up for up to 5
hours (not minutes!). Only then it is allowed to turn it ON again.
Visibility decreases and / or disappears.
Bright light sources (moon, projectors or headlights) may cause visibility
to degrade or even completely disappear. Move the scope away from the
light source immediately. The image should be restored in within 2
minutes. Poor atmospheric conditions such as fog, haze or extremely dark
environments, will decrease the visibility distance of the unit
8. WARRANTY
NEWCON OPTIK warrants this product against defects in material and
workmanship for 3 months from the date of the original date of
consumer's purchase, but no more than 12 months from the date of
production being indicated and stamped on the acceptance certificate
purchase. Should your NEWCON product prove defective during this
period, please bring the product securely packaged in its original
container or an equivalent, along with proof of the date of original
purchase, to your NEWCON Dealer. NEWCON will repair (or at its
option replace), the product or part thereof, which, on inspection by
NEWCON, is found to be defective in materials or workmanship.
What This Warranty Does Not Cover:
NEWCON is not responsible for warranty service should the product fail
to be properly maintained or fail to function properly as a result of
misuse, abuse, improper installation, neglect, damage caused by disasters
such as fire, flood, and lightning, improper electrical current, or service
other than by a NEWCON Authorized Service. Postage, insurance, or
shipping costs incurred in presenting your NEWCON product for
warranty service is your responsibility. Please include a check or money
order made out to NEWCON OPTIK for the amount of US$10.00 to
cover shipping and handling.
Features:
•
One stage image intensifier tube with Multi alkaline photocathode and image
intensifier tube gain of no less than 500 times ensures observation at ¼ moon
and better conditions
;
• Optional AP 12 Infra Red illuminator allows observation in complete
darkness
• Stargate M is intended for use within the range of illumination from 5/1000
lux to 1 lux at ambient temperature from-25’C to +40’C and relative humidity
of no more than 80% at 20’C.
• High quality wide-angle lens.
• The internal lens with focusing mechanism ensures adjustment for sharpness
for both near and remote objects
• The eye piece allows dioptric adjustment for the eyes
• Soft rubber eye-cap protects from the disturbing lateral light and occasional
impacts, thus making surveillance more comfortable;
• Original compact design and ergonomic shape make the device handy and
comfortable to hold with one hand
2. COMPONENTS
Stargate M is supplied with the following components:
NAME QUANTITY
Stargate M N.V, monocular 1
AP 12 I/R illuminator (optional) 1
Carrying strap 1
Case 1
Manual 1
Warranty Registration Card 1
3. SPECIFICATIONS of Stargate M
Magnification, x 2
Field of View, degrees, not less 20º
Dioptric Compensation, Dptr., no less ±4
Focusing Range, m 3-∞
Lens focal length, mm 35
Eyepiece focal length, mm 9.5
Power Supply: The monocular needs no batteries
AP 12 I/R illuminator CR 123 Lithium Battery
Dimensions, mm 160X60X65
Weight, kg 0.450
NOTE: As the design is being continuously improved some descriptions may