Installation Guide
Table Of Contents
- NEWAGE PRODUCTS INC. OUTDOOR KITCHEN PLATINUM PIZZA OVEN MANUFACTURER WARRANTY
- Safe Operating Practices
- Parts Supplied
- Tools Needed
- Product Inspection
- Product Specifications
- Installing Pizza Oven on NewAge Cabinet & Carts
- Installing Pizza Oven on custom built cabinet
- Assembling the Pizza Oven
- Leak Testing Instructions
- Fixing a Gas Leak
- Connection to AC
- Optional Accessories
- Pre-Operating Checklist
- Operating the Pizza Oven
- Proper Burner Position and Operation
- Pizza Oven Maintenance and Cleaning
- Troubleshooting
- Electrical Wiring Diagram
- Exploded View and Spare Parts
- GARANTIE DU FABRICANT DU FOUR À PIZZA PLATINUM OUTDOOR KITCHEN
- Pratiques d’exploitation sûres
- Pièces fournies
- Outils requis
- Inspection du produit
- Spécifications du produit
- Installation d’un four à pizza sur un meuble et un chariot NewAge
- Installation d’un four à pizza sur un meuble construit sur mesure
- Assemblage du four à pizza
- Instructions de Test d’Étanchéité
- Réparer une fuite de Gaz
- Connexion au CA
- Accessoires optionnels
- Liste de contrôle préfonctionnement
- Liste de contrôle préfonctionnement
- Utilisation du four à pizza
- Position et fonctionnement corrects du brûleur
- Entretien et nettoyage du four à pizza
- Remplacement des ampoules
- Dépannage
- Schéma de câblage électrique
- Vue éclatée et pièces de rechange
24
Assembling the Pizza Oven
Note:
This product must be installed by a licensed gas tter when installed within the State of
Massachusetts.
• Calculate the total BTU output of all equipment and refer to Gas Supply Line Runs for allowable
run distances for ¾ inch pipe. Failure to meet these minimum requirements may reduce
performance of the Pizza Oven and any other appliances running on that supply line.
• Always keep supply line runs as short as possible.
• A gas shut-o valve must be installed in an easily accessible location by a licensed gas tter.
• The outdoor cooking gas appliance and its individual shut-o valve must be disconnected from
the gas supply piping system during any pressure testing of that system at test pressures in
excess of 0.5 psi (3.5 kPa).
• The outdoor cooking gas appliance must be isolated from the gas supply piping system by
closing its individual manual shut-o valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psi (3.5 kPa).
• Keep threading compound o of the rst two pipe threads to avoid having any small pieces of
compound break loose and clog a burner valve or orice. Do not use threading compound on
any are ttings.
For built-in installations, it is recommended that any exible pipe used be kept as short as possible.
For freestanding units using natural gas, NewAge strongly recommends using a quick disconnect
kit. This Quick Disconnect kit, is included with purchase.
PIZZA OVEN
Intake
Manifold
Threaded
nipple
Flexible Gas
Hose
Quick
Disconnect
Threaded
nipple
Quick
Disconnect
Coupler
Main shut-off valve
Gas supply line
from meter
Flexible
Gas Hose
This illustration is for reference only
each installation will be different.