This product must be installed by a licensed gas tter when installed within the State of
Massachusetts.
Calculate the total BTU output of all equipment and refer to Gas Supply Line Runs for allowable
run distances for ¾ inch pipe. Failure to meet these minimum requirements may reduce
performance of the Pizza Oven and any other appliances running on that supply line.
Always keep supply line runs as short as possible.
A gas shut-o valve must be installed in an easily accessible location by a licensed gas tter.
The outdoor cooking gas appliance and its individual shut-o valve must be disconnected from
the gas supply piping system during any pressure testing of that system at test pressures in
excess of 0.5 psi (3.5 kPa).
The outdoor cooking gas appliance must be isolated from the gas supply piping system by
closing its individual manual shut-o valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psi (3.5 kPa).
Keep threading compound o of the rst two pipe threads to avoid having any small pieces of
compound break loose and clog a burner valve or orice. Do not use threading compound on
any are ttings.
For built-in installations, it is recommended that any exible pipe used be kept as short as possible.
For freestanding units using natural gas, NewAge strongly recommends using a quick disconnect
kit. This Quick Disconnect kit, is included with purchase.
PIZZA OVEN
Intake
Manifold
Threaded
nipple
Flexible Gas
Hose
Quick
Disconnect
Threaded
nipple
Quick
Disconnect
Coupler
Main shut-off valve
Gas supply line
from meter
Flexible
Gas Hose
This illustration is for reference only
each installation will be different.