TABLE 14A: BECKETT AFG BURNER SPECIFICATIONS
Beckett AFG
Boiler Model
Firing Rate
GPH
Settings Nozzle
3
Pump
Pressure
Head
(Setting)
Air
Shutter
Air
Band
GPH x Angle Type
2
Shipped
1
CL3-091
0.65 L1 8 0 0.55 x 70B (Delavan)
p Loose
140
p CL3-105
0.75 L1 6 0 0.65 x 45B (Hago) Installed 140
CL3-140 1.00 L1 10 1 0.85 x 45B (Hago) Installed 140
CL4-126 0.90 L1 7 0 0.75 x 45B (Delavan) Installed 140
CL4-175 1.25 V1(0) 10 1 1.00 x 45B (Hago)
Loose
175
CL4-210
1.50 V1(3) 10 2 1.10 x 45B (Hago) Installed 175
CL5-168 1.20 V1(3) 10 0 0.90 x 45B (Hago) Installed 175
CL5-245 1.75 V1(3) 7 3 1.35 x 45B (Hago) Installed 175
CL5-280 2.00 V1(4) 10 3 1.50 x 45B (Hago) Installed 175
1
Beckett low ring rate bafe required on CL3-091 (0.65 GPH) application only; shipped loose with nozzle.
2
Nozzle(s) for alternate boiler model ring rate(s) are shipped loose in bag attached to the
burner designated by corresponding symbol, i.e. (p) = CL3-105.
3
Single stage fuel pump is standard, two stage fuel pump is optional. Burner manufacturer has preset
single stage fuel pump to settings shown in table above.
XI: BURNER SPECIFICATIONS