Product Overview
Ratings, Specifications, & Dimensions
Standard Features
• Fully packaged
• Integrated boiler control system
• Beckett AFG oil burner - burner
packaged separately for easier handling
• Beckett GeniSYS primary control
• Electronic ignitor 14KV
A
S
M
E
H
MADE IN
U.S.A.
• Taco 007e circulator
• Metal section connectors
• Combustion target wall
• Vertical flue design
• Insulated jacket designed
for easy removal
• Relief valve
RELIEF VALVE
FLAME
OBSERVATION
PORT
FLUE
COLLAR
‘A’
‘B’
‘C’
DIA.
BUILT-IN DOMESTIC
WATER HEATER W/
3/4” CONNECTIONS
BOILER CONTROL
OIL BURNER
W/ PRIMARY
CONTROL
TEMP/PRESSURE
GAUGE
SUPPLY
24
5
8
“
14
1
2
“
12
1
4
“
3
5
8
“
2
1
8
“
1
1
2
“
3
3
4
“
5“
1
3
8
“
RETURN
31
5
8
“
1
1
2
“
DRAIN VALVE
BURNER SWING DOOR
CLEARANCE (OPEN 90°)
FLOOR
LINE
SEE NOTE 2
FRONT VIEW RIGHT SIDE VIEW
3
1
2
“
11”
9”
THE
NEW YORKER
Model
DOE
Heating
Capacity
(MBH)
AHRI
Net
Ratings
(MBH)
Burner
Capacity
(GPH)
AFUE
(%)
Minimum
Chimney
Requirements
Tankless
Heater
(GPM)
Jacket
Depth
'A'
Jacket
Rear to
Center
of Flue
'B'
Flue
Collar
Diameter
'C'
Approx
Ship
Wt.
(lbs.)
CL3-105WE 92 80 0.75 87.0 8" x 8" x15' 3.00 17-3/8" 8-1/4" 5-7/8” 560
CL3-140WE 122 106 1.00 86.3 8" x 8" x15' 3.25 17-3/8" 8-1/4" 5-7/8” 560
CL4-168WE 148 129 1.20 87.0 8" x 8" x15' 3.75 22-3/8" 10-7/8" 6-7/8” 680
CL4-210WE 182 158 1.50 86.0 8" x 8" x15' 4.00 22-3/8" 10-7/8" 6-7/8” 680
CL5-245WE 214 186 1.75 86.4 8" x 8" x15' 4.25 27-3/8" 13-3/8" 7-7/8” 800
CL5-266WE 231 201 1.90 86.0 8" x 8" x15' 4.75 27-3/8" 13-3/8" 7-7/8” 800
© 2020 New Yorker Boiler Company, Inc, Lancaster, PA
info@newyorkerboiler.com
www.newyorkerboiler.com
PL81420101006 - 9/20 - 2.5Ms
Notes:
1. Circulator supplied loose — may be installed on supply or return.
2. Return fittings and drain valve shipped loose.
3. Piping shown hidden not furnished with boiler.
C
OPTIONAL