Install Instructions

47
110503-01 - 4/20
CL Installation & Service Manual
Table 15-1: Beckett
Boiler Model
Firing
Rate
GPH
Burner
Model
Settings
Nozzle Shipped
Pump
Pressure
Head
(Setting)
Air
Shutter
Air
Band
CL3-105WE 0.75
AFG
L1
10 2 0.65 X 60B (Hago) Installed
140
CL3-140WE 1.00 5 2 0.85 x 60B (Hago) Field Provided
CL4-168WE 1.20
V1(0)
10 0.5 1.00 x 60B (Hago) Installed
CL4-210WE 1.50 10 6 1.25 x 60B (Hago) Field Provided
CL5-245WE 1.75 V1(3) 6 6 1.50 x 45B (Hago) Installed
175
CL5-266WE 1.90 V1(4) 8 4 1.35 x 45B (Hago) Field Provided
Boiler
Model
Firing
Rate
Burner
Model
Settings
Nozzle Shipped
Pump
Pressure
Head Bar Air Band
CL3-105WE 0.75
EZ-1 HP
0.60/.065 0.6 0.60 x 60A Delavan) Installed
150
CL3-140WE 1.00
0.85-1.00
0.75 0.85 x 60B (Delavan) Field Provided
CL4-168WE 1.20 1.00-1.10 1.00 x 60A (Delavan) Installed
CL4-210WE 1.50 1.10/1.25 1.25-1.35 1.25 x 60B (Delavan) Field Provided
CL5-245WE 1.75 EZ-2 HP 1.5 1.75 1.50 x 60A (Delavan) Installed
CL5-266WE 1.90
15 Burner Specifications
Table 15-2: Carlin