User Guide

4
110118-01 12/19
CG-F
Installation, Operating & Service Manual
Figure 1-3: Minimum Closet Clearances
Figure 1-4: Minimum Alcove Clearances
Model 'W'
CG30E 14"
CG40E 16"
CG50E 19"
CG60E 22"
CG70E 25"
CG80E 28"
Model 'W'
CG90E 31"
1 Dimensional and Physical Data (continued)
* Minimum radial clearance around vent pipe and breeching for single-wall metal pipe vent connector.
Otherwise, follow vent connector manufacturer's recommended clearances.
** Additional height required to maintain 6" clearance from all breeching components. Vent damper may
be installed in vertical or horizontal section of vent connector within reach of vent damper harness.
*** Area of each opening to be 1 sq. inch for each 1000 BTU/hr input - with minimum of 100 sq. inches. Height
of opening should be half of width. 3" minimum dimension for air openings.