User Guide

4
TABLE OF CONTENTS
I. General Information ................................ 5
II. Pre-Installation ........................................7
III. Water Piping and Trim ..........................10
IV. Venting ..................................................15
V. Electrical................................................17
VI. Oil Piping ..............................................21
VII. System Start-Up ..................................... 23
VIII. Operating ..............................................31
IX. Maintenance & Service Instructions ...... 36
X. Boiler Cleaning .....................................38
XI. Troubleshooting ....................................40
XII. Repair Parts ...........................................44
XIII. Beckett AFG Burner Parts for
AP-U™ Series Boilers .............................48
XIV. Riello Burner Parts for
AP-U™ Series Boilers .............................50
Appendix A - Low Water Cut O ........... 51
WARNING
This boiler contains very hot water under 12 - 15 PSI pressure. DO NOT unscrew any pipe ttings nor
attempt to disconnect any components of this boiler without positively assuring the water is cool and has
no pressure. Always wear protective clothing and equipment when installing, starting up or servicing this
boiler to prevent scald injuries. DO NOT rely on the pressure and temperature gauges to determine the
temperature and pressure of the boiler. This boiler contains components which become very hot when
the boiler is operating. DO NOT touch any components unless they are cool.
High water temperatures increase the risk of scalding injury. If this boiler is equipped with a tankless
heater for domestic water supply, a ow regulator and automatic mixing valve must be installed properly
in tankless heater piping. See Water Piping and Trim Section of this manual for details.
This boiler needs fresh air for safe operation and must be installed so there are provisions for adequate
combustion and ventilation air.
This boiler must be connected to an approved chimney or vent system in good condition. Serious
property damage could result if the boiler is connected to a dirty or inadequate chimney or vent system.
The interior of the chimney ue must be inspected and cleaned before the start of the heating season for
any obstructions. A clean and unobstructed chimney ue is necessary to allow noxious fumes that could
cause injury or loss of life to vent safely and will contribute toward maintaining the boiler's efciency.
DO NOT operate boiler with the absence of an approved vent system.
This boiler is supplied with controls which may cause the boiler to shut down and not re-start without
service. If damage due to frozen pipes is a possibility, the heating system should not be left unattended in
cold weather; or appropriate safeguards and alarms should be installed on the heating system to prevent
damage if the boiler is inoperative.
This boiler is designed to burn No. 2 fuel oil only. DO NOT use gasoline, crankcase drainings, or any
oil containing gasoline. Never burn garbage or paper in this boiler. DO NOT convert to any solid fuel
(i.e. wood, coal). DO NOT convert to any gaseous fuel (i.e. natural gas, LP). All ammable debris, rags,
paper, wood scraps, etc., should be kept clear of the boiler at all times. Keep the boiler area clean and
free of re hazards.