Specifications
Z-Wave Mini Smart Plug
• N4001 •
2. Your device may need to be within 100 feet of the controller to be included. If so,
include the device to the network within 10 feet of the controller and relocate it to
the desired position in your home. Be sure to refresh the network if the device is
included in this manner.
1. Plug the device you want to control into the Z-Wave Smart plug controlled outlet.
NOTE: Plug directly into the outlet, do not use with extension cords.
Parameter Settings
100 feet
Features:
Notes:
Our Products warrants this product to be free from manufacturing defects for a period
of one year from the original date of consumer purchase. This warranty is limited to the
repair or replacement of this product only and does not extend to consequential or
incidental damage to other products that may be used with this product. This warranty
is in lieu of all other warranties, expressed or implied. Some states do not allow
limitations on how long an implied warranty lasts or permit the exclusion or limitation
of incidental or consequential damage, so the above limitations may not apply to you.
This warranty gives you specific rights, and you may also have other rights which vary
from state to state.
Warranty
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave network with
other Z-Wave certified devices from other manufacturers and/or other
applications. All non-battery operated nodes within the network will act as
repeaters regardless of vendor to increase the reliability of the network.
This Device supports Lifeline (association group 1) supporting 1 node for
lifeline communication.
Group 1 must be assigned the Node ID of the primary controller where
unsolicited notifications will be sent. The Z-Wave controller should set this
association automatically aer inclusion.
Lifeline association only supports the “Device Reset Locally” function.
1. Z-Wave on/off control.
2. Z-Wave controlled AC outlet for standard incandescent lighting,
CFL/LEDs, fans or small appliances(1800W Resistive Max).
3. Grounded 3-wire power connection for safety.
4. Remembersandrestoreson/offstatusaerpowerfailure.
5. Built-inZ-WavePlussignalrepeatertoextendnetworkrange.
6. S2 security and 500 Z-Wave chip for reliable wireless communication.
7. Work with all certificated Z-Wave controllers.
WARNING
RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
TO REDUCE THE RISK OF ELECTRIC SHOCK, THIS PRODUCT HAS A GROUNDING TYPE PLUG THAT HAS A THIRD
(GROUNDING) PIN. THIS PLUG WILL ONLY FIT INTO A GROUNDING TYPE POWER OUTLET. IF THE PLUG DOES NOT
FIT INTO THE OUTLET, CONTACT A QUALIFIED ELECTRICIAN TO INSTALL THE PROPER
OUTLET. DO NOT CHANGE THE PLUG IN ANY WAY.
CONTROLLING APPLIANCES:
CAUTION: TO REDUCE THE RISK OF
OVERHEATING AND POSSIBLE DAMAGE TO
OTHER EQUIPMENT
• DO NOT EXCEED RATINGS
• DO NOT USE TO CONTROL ANY DEVICE
WHERE UNINTENDED OPERATION COULD
CAUSE UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP, ETC.)
Generic Device Class:
0x10 - GENERIC_TYPEGENERIC_TYPE_SWITCH_BINARY
Specific Device Class:
0x01 - SPECIFIC_TYPESPECIFIC_TYPE_POWER_SWITCH_BINARY
Command Classes:
0x5E - COMMAND_CLASS_ZWAVEPLUS_INFO_V2,
0x25 - COMMAND_CLASS_SWITCH_BINARY,
0x85 - COMMAND_CLASS_ASSOCIATION,
0x8E - COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
0x59 - COMMAND_CLASS_ASSOCIATION_GRP_INFO,
0x55 - COMMAND_CLASS_TRANSPORT_SERVICE_V2,
0x86 - COMMAND_CLASS_VERSION,
0x72 - COMMAND_CLASS_MANUFACTURER_SPECIFIC,
0x5A - COMMAND_CLASS_DEVICE_RESET_LOCALLY,
0x73 - COMMAND_CLASS_POWERLEVEL,
0x70 - COMMAND_CLASS_CONFIGURATION,
0x9F - COMMAND_CLASS_SECURITY_2,
0x6C - COMMAND_CLASS_SUPERVISION
0x7A - COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
LED Indicator
This parameter can access you to choose the led indicator to be on when the
switch(light) is on/off, or LED indicator remains on/off all times.
(LED flashes 2 times when the configuration parameter changed.)
Operation: quickly press 6x: change parameter
--Parameter =1, size =1 byte,
value=00(default) LED is On when switch(light) On and LED is Off when the
switch(light) Off.
value=01 LED is On when the switch(light) Off and LED is Off when the
switch (light) On.
value=02 LED is disabled
Auto Turn-Off Timer
This parameter can access you to set a timer to make the switch turn off
automatically aer the switch turned on.The number entered as value corresponds
to number of minutes.
(LED flashes 2 times when the configuration parameter changed.)
Operation: Set up on the hub.
--Parameter =2, size=4 byte, value range: 0 – 65535 (Min),
Value=0(default) turn off the outlet
Auto Turn-On Timer
This parameter can access you to set a timer to make the switch turn on automatically
aer the switch turned off.The number entered as value
corresponds to number of minutes.
(LED flashes 2 times when the configuration parameter changed.)
Operation: Set up on the hub.
--Parameter =4, size=4 byte, value range: 0 – 65535 (Min),
Value=0(default) turn on the outlet
Restores state aer power failure
This parameter can access you to set the switch to be on/off aer power failure.
(LED flashes 2 times when the configuration parameter changed.)
Operation: Quickly press the button 10 times (Please note: the switching of
each value is in order, a quick press on the button 10 times will switch once.
eg: Switching from value 0 to value 2 needs 2 switching. )
--Parameter=6,Size=1
Value=0-----------The switch is off regardless of the state prior to power failure.
Value=1-----------The switch is on regardless of the state prior to power failure.
Value=2(default)-----------This switch will be return to state prior to the power
failure aer power is restored.
Power: 125VAC, 60Hz
Loading: 15A Max Resistive
Frequency: 908.42MHz
Temperature Range: 32° F ~104° F
Program button
Press 1x: On/Off
Press 3x: Z-Wave Network configuration.
LED indicator:
Device output status, LED on with output on
Add/Removed: blue LED flashing 30s
Indoor use in dry location
1. Follow the instructions for your Z-Wave certified controller to remove a device
from the Z-Wave network.
2. Once the controller is ready to remove your device, press the manual/program
button on the smart plug 3 times quickly.
Adding Device To Z-Wave Network
To Remove The Device
Again: If you have issues with pairing/including, please move the device as close as
possible to the hub and try again--you can move to your final location when
completed.
Note: If the manual button doesn't light up after pressed 3 times, please reset the
device: click the button 2 times quickly then hold for at least 10 seconds. This
operation could be done when manual control is functional--single press can turn
on/off the lamp.
1. Follow the instructions for your Z-Wave certified controller to add a device to the
Z-Wave network.
2. Once the controller is ready to add your device, press the Manual/ Program button
on the smart plug 3 times quickly. The blue LED will blink quickly.
Auto-add mode: LED will blink within 30 seconds after first plugged in.
Manual: Click the button 2 times quickly then hold for at least 10 seconds .
Host reset: Remove it from hub the device will factory reset.
To Return The Device To Factory Defaults:
(LED flashes 2 times when the configuration parameter changed.)
Support 2 groups, each group max support 5 devices
Group 1 lifeline
Group 2 Le outlet send basic set
Now, you have complete control to turn your fixture ON/OFF according to groups,
schedules and interactive automation programmed by your controller. If your
Z-Wave certified controller features remote access, you can control your fixture
from your mobile devices.
Z-Wave Network Configuration
CAUTION - PLEASE READ!
This device is intended for installation in accordance with the National Electric Code and local regulations in the
United States, or the Canadian Electrical Code and local regulations in Canada. If you are unsure or uncomfortable
about performing this installation consult a qualified electrician.
Please exercise EXTREME CAUTION when using Z-Wave devices to control appliances. Reason being is because
the appliance you want to control may be in a separate room and if unintentional behavior occurs (such as
adevice turning on or off - either intentionally via schedules, or unintentionally via network error) this event may
lead to a hazardous condition. For these reasons, please note the following suggestions:
1) Do not include Z-Wave devices in Groups or Scenes if they control appliances.
2) Do not use Z-Wave devices to control electric heaters or any other appliances which may present a hazardous
condition due to unattended, unintentional, or automatic power control.
Please DO NOT use this switch to control Medical or Life Support equipment. Z-Wave devices should never be
used to control the On/Off status of Medical and/or Life Support equipment.
MEDICAL EQUIPMENT
CONTROLLING APPLIANCES
This device complies with part 15 of the FCC and Industry Canada license-exempt RSS standard(s). Operation is
subjected to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
To comply with the FCC RF exposure compliance requirements, no change to the antenna or
the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF
exposure requirements and void user’s authority to operate the device.
The manufacturer is not responsible for any radio or TV interference caused by unauth
orized
modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
FCC / IC
FCC NOTE:
NOTE:
Important note:
Association
Please contact us if you have any questions:
ask@newone-tech.com
www.newonetree.com
™
Specification:
SIZE: 220 x 220 mm
材质:80G 书写纸
拆法:风琴页 55 x 65 mm 成品
正面