Owner manual

New Era Pump Systems Inc.
www.SyringePump.com
Model NE-4000 Multi-Phaser
Publication #1200-01
44
09/05/14
11.
Appendix
11.1
RS-232 Command Summary
<command> =>
DIA [ < float > ] Syringe inside diameter
PHN [ < phase data > ] Program Phase number
FUN [ < phase function > ] Program Phase function
< phase function > =>
RAT Pumping rate. ‘RATE
FIL Fill syringe to volume dispensed. ‘FILL
INC Increment rate. ‘INCR
DEC Decrement rate. ‘DECR’
STP Stop pump. ‘STOP’
JMP <phase data> Jump to Program Phase. ‘JP:nn’
PRI Sub-Program Selection Input. 'Pr:In'
PRL <number data> Sub-Program Start Label definition. 'Pr:nn'
LPS Loop starting Phase. ‘LP:ST’
LOP <count data> Loop to previous loop start ‘nn’ times. ‘LP:nn
LPE Loop end Phase. ‘LP:EN’
PAS <number data> Pauses pumping for ‘nn’ seconds. ‘PS:nn’
PAS [n.n] Pauses pumping for 'n.n' seconds. 'PS:n.n'
IF <phase data> If Program input low, jump to Program Phase. ‘IF:nn’
EVN <phase data> Set event trigger. ‘Et:nn’
EVS <phase data> Set event square wave trigger. 'ES:nn'
EVR Event trigger reset. ‘Et:RS’
CLD Clear total dispense volume. ‘CLR.D
TRG <nn> Override default operational trigger configuration ‘tr:aa’
BEP Sound short beep. ‘BEEP
OUT { 0 | 1 } Set programmable output pin. ‘OUT.n’
RAT [C | I ] [ <float> [ UM | MM | UH | MH ] ] Pumping rate
VOL [ <float> | <volume units>] Volume to be Dispensed, or set Volume units
DIR [ INF | WDR | REV | STK ] Pumping direction
RUN [ <phase data> ] Starts the Pumping Program
[E [<phase data>] ] Pumping Program event trigger
PUR Start purge
STP Stop/pauses the Pumping Program or purge
DIS Query volume dispensed
CLD { INF | WDR } Clear volume dispensed
SAF [ <n> [ <n> [ <n> ] ] ] Safe communications mode
LN [ 0 | 1] Low motor noise mode
AL [ 0 | 1] Alarm buzzer mode
PF [ 0 | 1] Power failure auto-restart mode
TRG [ FT | FH | F2 | LE | ST | T2 | SP | P2 | RL | RH | SL | SH |OF ] Operational trigger default mode
DIN [ 0 | 1] Directional input control mode
ROM [0 | 1] Pump Motor Operating TTL output mode
LOC [ P ] [ 0 | 1]] Keypad lockout mode or Program Entry Mode lockout
BP [ 0 | 1] Key and Notification beep mode
OUT 5 { 0 | 1 } Set TTL output level
IN { 2 | 3 | 4 | 6 } Query TTL input level
BUZ [ 0 | { 1 [ < n > ] } ] Buzzer control
VER Query firmware version
System Commands: Valid regardless of current network address
*ADR [ <n> [<n>] [ B <baud-rate>] ] Network address and baud rate
*ADR [ DUAL | RECP | ALTR ] Set Reciprocating, Dual, or Alternating pumping mode
*RESET Resets pump. Clears program memory and resets setup.
------------------------------------------------------------------------------------------------------------------------------
Network Command Burst => <n> <command> * [Network Command Burst]
- Communicate simultaneously with multiple pumps on a pump network.
Any command preceded by the asterisk symbol ‘*’ bypasses the pump network address and Safe mode.