- Buck Stoves Owner's Manual VENT-FREE FP-BR-10-ZC
TROUBLESHOOTING 
WARNING 
TURN OFF BURNER, UNPLUG HEATER AND LET COOL BEFORE 
SERVICING. ONLY A QUALIFIED SERVICE PERSON SHOULD 
SERVICE AND REPAIR HEATER. 
CAUTION 
NEVER USE A WIRE, NEEDLE, OR SIMILAR OBJECT TO CLEAN 
ODS/PILOT. THIS CAN DAMAGE ODS/PILOT. 
OBSERVED 
PROBLEM 
1.  Igniter button is pressed, 
no spark at ODS/Pilot 
2.  Igniter button is pressed 
 Spark at ODS/Pilot 
 No Ignition 
POSSIBLE 
CAUSE 
1. Igniter  electrode 
positioned incorrectly. 
2.  Igniter electrode broken 
3.  Igniter electrode not con-
nected to igniter cable 
4. Igniter cable pinched or 
wet 
5.  Piezo igniter nut is loose 
6.  Broken igniter cable 
7.  Bad piezo igniter 
1.  Gas supply turned off or 
manual shutoff valve is 
closed 
2. Control knob not in 
“PILOT” position 
3.  Control knob not pressed 
in while in “PILOT” 
position 
4. Air in gas lines when 
installed 
SOLUTION 
1. Replace igniter 
2. Replace igniter 
3.  Reconnect igniter cable 
4.  Free igniter cable if 
pinched by any metal or 
tubing. Keep igniter 
cable dry. 
5. Tighten nut holding 
piezo igniter to heater 
cabinet. Nut is located 
inside heater cabinet at 
top 
6.  Replace igniter cable 
7.  Replace piezo igniter 
1.  Turn on gas supply or 
open manual shutoff 
valve 
2.  Turn control knob to 
“PILOT” position 
3.  Press in control knob 
while in “PILOT” 
position 
4.  Continue to hold down 
control knob. Repeat 
igniting operation until 
air is removed. 
Page 28